REX K-1-9 and REX K-3-9 – STANDALONE OR ACCESS
CONTROLLER
The Rex is a controller with built-in proximity card reader and keypad. It is
designed for residential and business buildings, offices, shops, etc. In various
operation modes, the controller allows access for up to 500 users (2 master
cards or codes + 500 user cards or codes). The controller can have 125kHz
or 13.56MHz reading frequency.
As a standalone controller, the entire set-up procedure is carried out with
master card or code. User cards and codes can either be registered or
deleted.
As an access controller, the entire set-up procedure is carried out with the
software.
The controller signals normal operation with flashing red and green LED It
can also be used as a Wiegand 26-bit reader, if needed.
TECHNICAL DATA
REX K
REX K-1-9 reading frequency
REX K-1-9 reading distance
REX K-1-9 current consumption
REX K-3-9 reading frequency
REX K-3-9 reading distance
REX K-3-9 current consumption
Dimensions (mm)
Protection
Communication
Operating voltage
Operating temperature
Cabel
Memory
Inputs
Outputs
Clock
Keypad
CONNECTION CABLE
Wire-Color
Description/Wiegand 26-bit
1 – red
9-14V DC
2 – gray
GND
3 – gray
El. strike output / Data 0
4 – gray
Alarm output/ Data 1
Door status switch input/ Buzzer
5 – gray
input
Push button input /
6 – gray
LED input
7 – gray
CA
8 – gray
CB
LED DIODES
Color
Flashing red/green
Lit green
Lit red
Black line
REX K-1-9 and REX K-3-9 – Standalone or access controller
125kHz
Up to 13cm
60mA
13.56MHz
Up to 7cm
90mA
58x120x17 (WxHxD)
IP65
RS485
From 9V to 14V DC
From -20°C to 70°C
Flat cable 20cm
500 cards or codes
500 events
Door status
Push button
Transistor output for el. strike 0.5A
Real time clock, battery backup
(max. ten hours)
Numeric, illuminated, with gold
plated contacts
Specification
Power supply
Ground
Max. 0.5A
Active = GND
Active = GND
Active = GND
Active = GND
RS485 A line
RS485 B line
Description
Normal mode
El. strike is unlocked
Card has no rights
Power supply
The controller need's external power supply to operate. The Spider W40
power supply is sufficient to power two controllers and two 12V electric
strikes or two 12V magnetic locks (0.5A). If you will use it as a standalone
controller and low consumption electric strike (0.25A) you can use power
supply Spider W5.
Voltage drops and cable signal interferences
When you connect the controller, use cable with a diameter of at least
2
0.22mm
. If the cable length exceeds 25m, use one twisted pair of UTP
cables for the positive (+) pole and one for the negative (-) pole. The cable
length between power supply and the controller should not exceed 50m.
Take into consideration that a 0.22mm
approximately 9 ohm per 100m. The power supply at the end of cable should
be a minimum of 9V. If you are using el. strike, it is highly recommended
that the voltage drop is calculated. At greater distances, a thicker cable of
2
0.5mm
or more should be used wherever possible.
If the load is, for example, 0.5A (with el. strike) then, on the 0.22mm
voltage drop will be 4.5V at 100m. For the device with 60mA consumption,
the voltage drop is 0.5V.
Reading distance depends on where the controller is installed. The presence
of metal or interferences can significantly reduce the reading distance. DO
NOT install the controller directly on metal surfaces and/or cover it with a
metal cover.
It is not recommended to install controllers closer than 30cm from each
other in any direction. Otherwise, it may result in inaccurate readings or,
indeed, in the controller not reading at all.
For the Rex K-3-9 to comply with EMC directives (CE), you have to
put ferrite core on the cable as close to the controller as possible,
making two turns!
Inputs, outputs and environment
Inputs:
Inputs are realized with opto-isolators. The input is active, when pulled to
ground with an open collector transistor or mechanical switch, which is
connecting the input pin of the controller to the Ground.
Outputs:
Output has a pre-installed protection diode for an inductive load. It is also
protected from current overload. The best way is to use a 0.25A el. strike or
a 0.5A el. magnet, which has to be connected to the same positive pole (+)
as the controller. Connect the negative pole (-) to the door strike output
(wire 3). When the output is active it is pulled to ground. This can be
changed with function 5 – negate output (for el. magnet).
Environment:
If the plastic housing is in a different color than black, then there is a chance
that the color will change (to some extend) in a few months or years if
exposed to direct sunlight.
The controller has IP65 protection, but you must
assure good cable joints, protected against moisture, otherwise corrosion
may damage the controller. Damage in such cases is not covered by the
warranty.
Reading range:
The controller has a program algorithm that, at power start, sets parameters
based on the installation environment, so as to ensure an optimal reading
range. DO NOT install the controller directly on metal surfaces and/or cover
it with a metal cover; it may stop working/reading. If you plan to test the
controller and move it onto different surfaces, then you have to reset it
(power off/on) on each surface.
Installation of Rex K
Remove black plastic screw covers on the top and the bottom of
the controller. Install the controller to the wall with two supplied
screws. Use diagonal holes - it enables a small correction of the
position of the controller (up, down, left, right). When the
controller is installed, put the screw covers back on.
2
cable has a resistance of
2
3/2015
www.jantar.si
cable

Advertisement

loading

Summary of Contents for Jantar REX K-1-9

  • Page 1 REX K-1-9 and REX K-3-9 – Standalone or access controller Power supply The controller need’s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes or two 12V magnetic locks (0.5A). If you will use it as a standalone controller and low consumption electric strike (0.25A) you can use power...
  • Page 2 REX K-1-9 and REX K-3-9 – Standalone or access controller AS A STANDALONE CONTROLLER Change the first master card on position 1: Enter the master code and press  . Press 0 and  . Press 1 and  . In three seconds approach the new master card.
  • Page 3 Door status switch input-normally closed (NC) Standalone controller –Approach a user card before 1. beep. Time is set in seconds Wiegand 26-bit reader (Jantar) – Approach a user card after 1 beep. The After 5. beep Sound is ON reader sends a card data at once and pressed buttons separately. This is Tamper is OFF used in Jantar’s systems, so that the controller distinguishes between a card...
  • Page 4 REX K-1-9 and REX K-3-9 – Standalone or access controller Changing back to standalone controller from access controller: After 8. beep Sound is OFF In the Codeks Device Manager software do the “Brainwash” of the Tamper is OFF Press 8 and ...

This manual is also suitable for:

Rex k-3-9