STEAK AGER INSTRUCTION MANUAL MODEL:DA127 MODEL:DA270 MODEL:DA388 Thanks for buying our Steak Ager, Hope our advanced product will give your meat a different joyful taste. Before use, please read and follow all safety rules and operating instructions.
Page 2
WARNING The information in this document is subject to modification without any prior notice. Some models are available in dedicated countries only. Offers no guarantee for our Steak Ager if it is being used for any purpose other than that for which it was specifically designed.
Page 3
Please operating the product only in the specified room temperature. DANGER: Risk of child entrapment. Before you throw away your old Steak Ager: - Take off the doors; - When disposing of the appliance, do so only at an authorized waste disposal centre. - Leave the humidor drawer in place so that children may not easily climb inside;...
Page 4
Attention: When the Steak Ager is at “OFF” condition: - Please take out all of goods from Steak Ager; - Please keep Steak Ager clean Allow 24 hours before switching on the Steak Ager. During this time we recommend that you leave the door open to clear any residual odors. BEFORE LOADING &...
Page 5
If the supply cord is damaged, it must be replaced by a qualified person in order to avoid electrical hazard. INSTALLING YOUR STEAK AGER Unpack and remove all of the protection and adhesive strips from the packaging around and inside the Steak Ager. The Steak Ager must be positioned such that the plug is accessible.
WARRANTY void. INSTALLATION DRAWINGS FOR BUILT IN STEAK AGER: (UNDERBENCH OR IN COLUMN) FRONT VENTING STEAK AGER ONLY. Note: The appliance must be positioned so that the plug is accessible after installed. DIMENSIONAL DRAWINGS: DA127...
Page 8
OPEN ANGLE SIZE DRAWINGS: DA127 DA270/ DA388...
Page 9
DA127/DA270/DA388 Models use side anti-dew tube and Independent cooling system. TURNING ON YOUR SEEAK AGER Plug in and switch on the cellar by pressing on the power button for a few seconds. When you use the Steak Ager for the first time (or restart the Steak Ager after having it shut off for a long time), there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout.
customers but will not retake possession of the goods due to complaints based on normal operating noise occurrences. STARTER -TIPS 1. Clean the inside of the Steak Ager with disinfectant, which shouldn’t be aggressive. 2. If ordered: unpack the salt blocks and remove the foil. Put the salt blocks in the stainless steel tray and place the tray in the middle of the fridge.
Page 11
TEMPERTURE DISPLAY BOARD OPERATING INSTRUCTION: Instructions for LED panel operation Function switch button: ① Press one time ,the window ④ and window ⑤ to switch temperature and humidity function, and press the button ⑥ or ⑦ to increase or decrease temperature and humidity. ON/OFF the power button: ...
Page 12
Instructions for LCD panel operation ON/OFF the power button: ① Press the button 3 seconds to power off. Remark: The other functions will turn off except light switch when the power turns off. Press again (without delay), the power turns on. Function switch button: ...
Set temperature display screen ⑩ Represents the temperature value of the display product setting Actual temperature screen Show the actual indoor temperature Humidity display screen Displays humidity settings and actual humidity The LED lighting in the box can be controlled by the door switch or by man-made control.
Page 14
REMOVING SHELF Shelf taking: According to below instruction drawing to press one side of shelf limit pin①, extract and remove the shelf from the other side of support bracket②, then take off the shelf following the arrow mark ③. Shelf installation will be opposite with shelf taking. 、”A”...
Page 15
2. After opening the water tank cover, you can see the water tank, take out the water tank according to the arrow direction; 3. Then rotate the water tank cover at the bottom of the water tank. After opening, you can add water.
REVERSIBILITY OF THE DOOR Warning: To avoid accidents during the process of changing the door, we recommend that you get assistance. The glass door is heavy and may cause injury if dropped. - Depending on to the model and the type of handle your Steak Ager is equipped with, you may have to rotate the door through 180 degrees.
Page 17
Door timeout alarm: More than 5 minutes after the door, has not closed, the alarm system lights flickering, prompt to close. The alarm lights are cleared automatically after closing the door. Handle Installation Method 1. Take out handle from cabinet, then take out 4pcs 4 * 35 screws from accessory bag 2.
OPERATION ANOMALIES Ensure that there is power to the electrical supply plug by connecting another electrical appliance to it. Check fuse, if any. Make sure that the door is closed properly. If your Steak Ager appears to be malfunctioning, unplug it and contact your our after sales service.
TROUBLESHOOTING GUIDE Common problems may easily be solved, saving you the cost of a possible service call. Please read carefully the instruction manual and revert to troubleshooting guide chart. PROBLEM POSSIBLE CAUSE Steak Ager does Not plugged in. not operate. The appliance is turned off.
Page 20
Before disposal of the appliance. 1. Disconnect the main plug from the main socket. 2. Cut off the main cable and discard it.