4. Operational method
4.1 The newly bought or long-time not used scales should be connected with power supplier
before using. Pull out the plug in order to charge the battery, it can be used normally while
recharging and "
4.2 "
" switch:Press "
Tare range", then shows "0", press this key to turn off.
4.3 "TARE": with empty scale platform, the displaying deviates from zero, pressing " TARE" key,
then the displaying will return to zero; If need to tare, first place the container on the platform,
after stabilizing, press "TARE" key, the scale displays"0". Then place the article in container, at
this time, it shows the net weight of the article, remove the article and the container, the scale
shows a negative value of container weight. Still press "TARE" to return to"0".
4.4 "
" : the units can be changed between "kg" and "lb"
4.5 COUNT: sampling of article by"COUNT" key to enter the counting state
4.5.1 Choose the quantity of samples: To precisely count the articles, firstly the quantity of
samples for counting should be chosen in according with the weights of the articles. The quantity
of samples can be chosen from"1-10-20-50-100". For a small number of articles, the larger
quantity of samples, the more precise.
4.5.2 Place one or more samples on the empty pan, the balance will show the total weights of
samples. Then press "COUNT", the displaying will show "1", at the same time, the displaying
show unit "pcs", with indicate that scale is now counting. And all the samples are one unit. Then
", the displaying will show between"1-10-20-50-100". The quantity of articles and
press"
samples must be the same, and place the similar articles. The total amount of objects is showed,
press the "COUNT"again back to the normal situation.
4.6 Calibration Method
Hold on "TARE" and press "
"CXXXX-" (XXX should be the weight of standard weights, for example: when displaying
showing "C 100" expressed the need to place a standard weight 100kg) and enter into calibration
status, place the calibrating weight on the platform,after stability, the scale displays the weight of
the calibrating weights and the unit "kg" , till now the calibration is completed and the scale can
be normally used. Under the calibration status, press "TARE", it will quit.
PS: Setting and meaning
Press and hold on "
mode, pressing "
" to change the parameters, pressing "TARE" to change the values of
parameter.
1. C1......Sensitivity setting 0 1 2 3 4, the larger number is, the less sensible but the better stable.
Default setting is 2 or 1.
C2----Filtering strength setting 0 1 2 3, the larger number is, the lower reaction speed but the
better stable. Default setting is 2 or 1.
C3---- Battery save mode, "0": no saving mode, "1": turn off the data display when stabilization
for 3 minutes, "2": turn off the data display when stabilization for 3 minutes, auto power-off after
1 hour. Default setting is 2.
C4----For this series no use..
C5----bright display mode. 0: darker than 1 ; 1: normal ; 2:lighter than 1 ; Default setting is 1.
" will flicker on the display, disappear when full.
" when the scale is off, the display will show "ON, Voltage,
"when the scale is at zero point, the display shows
" to turn on the scale, displays "ON, voltage" and then enter into setting