Mitsubishi Electric MELIPC MI5000 Series Programming Manual page 62

Vxworks
Hide thumbs Also See for MELIPC MI5000 Series:
Table of Contents

Advertisement

CCPU_ResetWDT
Resets a user WDT of the VxWorks part.
Format
short CCPU_ResetWDT(short sType)
Argument
Argument
sType
Description
• Resets a user WDT of the VxWorks part.
• When this function is executed without the user WDT running, an error will be returned.
Return value
Return value
0(0000H)
-220(FF24H)
-28158(9202H)
-28629(902BH)
For details on error codes, refer to the following section.
Page 116 Function error codes
Relevant function
Page 35 CCPU_EntryWDTInt
Page 71 CCPU_StartWDT
Page 72 CCPU_StopWDT
3 DETAILS OF FUNCTIONS
60
3.1 C Controller Module Dedicated Functions
Name
WDT type
Description
Normal
WDT type error
WDT error
WDT not started error
Description
Specify the WDT type.
(When 'Reserved' is specified, an error is returned.)
• 0: User WDT
• Others: Reserved
IN/OUT
IN