Pump External Control Mode:
For proper operation with IntelliSync, the
pump should NOT be in External Control
Only mode (Green LED on). The green LED
next to Ext. Control Only should not be
illuminated.
To take the pump out of Ext. Control Only
mode, press the Start/Stop button to stop
the pump. Press and hold the Start/Stop
button for at least 10 seconds. The green
LED should go out next to Ext. Control Only.
Operating the SuperFlo VS/VST, SuperMax VST pump:
The SuperFlo VS/VST, SuperMax VST pumps have four (4) default
speed settings for speeds 1, 2, and 3 and the QuickClean feature.
Speeds can only be adjusted on the pump's control key pad.
Pump Speed Priority (Speed 1, Speed 2, Speed 3, and QuickClean):
The lowest speed number will take priority over the highest speed
number. The priority in which speeds will run is Speed 1 has the
highest priority then Speed 2, Speed 3, and Quick Clean.
Example: A recommended set up would be to set Speed 2 for the
pump filtration speed, and set a lower speed for Freeze protection
on Speed 3. If the temperatures drops to the freeze set point, the
pump will run at a low speed to keep the pool water from freezing.
When it's time to run the pump filtration schedule, the pump will ramp
up to the filtration speed since it's set as speed 2 and has higher
priority. As a rule, set up higher RPMs on the lower speed number
buttons and lower RPMs on the higher speed buttons.
Note: If the pump has been stopped via the Start/Stop button, the pump will not
run until the pump is turned back on by pressing the Start/Stop button. If the Start/
Stop LED is illuminated, that indicates the pump is on and will run via Digital Inputs.
Note: When multiple low voltage triggers are present priority will be: PROGRAM 1 >
PROGRAM 2 > PROGRAM 3 > QUICK CLEAN.
Set the pump schedules to zero: To ensure any existing schedules on the pump
do not conflict with the IntelliSync schedules, all schedules need to be set to zero
duration for the pump to work properly.
To zero out the pump schedules:
1.
Stop the pump. Press the desired speed button until the duration LED is
blinking.
2.
Press the arrow button to set each schedule duration to 0:00 (hr. min.)
3.
Repeat Steps 1-2 for all speed buttons (1, 2, and 3).
Continue to next page.