Important Information And Precautions; Important Instructions For Using The Bat 250; Starting With A Battery In The Vehicle; Starting With A Defective Battery Or No Battery In The Vehicle (Battery Replacement Mode) - Bosch BAT 250 Original Instructions Manual

Battery starter for 12 volt vehicle electrical systems
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
en
16 | BA� 2�� | Important information and precautions
4.
Important information and
precautions
4.1
Important instructions for using the
BA� 2��
The BAT 250 must only be used to start vehicles with
a 12 Volt vehicle electrical system.
Before using the BAT 250, please read the operating
instructions carefully.
Always stand the BAT 250 in an upright position on a
firm base.
Connect the terminal clips securely to the vehicle bat-
tery terminals, ensuring correct polarity.
Ensure that the BAT 250 is switched off before releas-
ing the terminal clips from the vehicle battery.
Each time it is switched on, the BAT 250 checks the
status of its internal battery. The charge status of
the internal battery is displayed for 10 s by means of
LEDs (Fig. 3, Pos. 3, 4 or 5).
Every time the BAT 250 is activated, the terminal pli-
ers connection is evaluated and the result displayed
by LEDs 6 - 8 (see Ch. 3.4). Therefore, always con-
nect the terminal pliers before activating BAT 250. No
evaluation is performed during operation except if the
terminal pliers are disconnected from the battery.
The BAT 250 recognizes the end of the start-up proc-
ess. If the engine starts, the BAT 250 switches off
automatically.
In "battery replacement mode" there is no safety
monitoring. Ensure correct polarity.
For safety reasons, only trained personnel who are
familiar with its operation may use the battery starter.
Exercise caution when opening the BAT 250. The bat-
tery is charged. Risk of short-circuit at the terminals.
Always use insulated tools.
To avoid a damaging exhaustive discharge of the
internal battery, the ON period for the BAT 250 is
restricted to 4 h in all operating modes. The voltage of
the internal battery is continuously monitored accord-
ing to the operating mode. The BAT 250 shuts down if
a critical limit is violated.
|
1 689 979 899
2012-10-18
4.2

Starting with a battery in the vehicle

1. Connect the terminal clips on the starter cable
(Fig. 1, Pos. 6) to the vehicle battery, ensuring cor-
rect polarity.
$
Red terminal clip (+) to the positive terminal on
the battery.
$
Black terminal clip (–) to the negative terminal on
the battery.
2. Press the ON/OFF button (Fig. 2, Pos. 1) briefly.
 The BAT 250 is ready when LED 6 lights up green.
i
If LED 7 lights up red, the polarity has been re-
versed. If LED 7 lights up red and LED 8 lights up
yellow, there is no contact with the battery or the
vehicle has no battery.
3. Start the vehicle.
 If the engine starts:
The BAT 250 switches off automatically, the termi-
nal clips are de-energized.
 If the engine does not start within 10 s:
The starting process is automatically terminated
after 10 s. A new start attempt can be made after
a waiting time of 5 s.
4. Disconnect the terminal clips on the starter cable
from the vehicle battery
4.�
Starting with a defective battery or
no battery in the vehicle (battery
replacement mode)
If the vehicle has
R
a defective battery or
R
no battery or
R
if the vehicle to be started has an electronic immobi-
lizer or an additional starting relay,
it can be started in "battery replacement mode".
i
Every time the BAT 250 is activated, a check is
performed to see if polarity is correct of if a short
circuit has occurred. Therefore, always connect the
terminal pliers before activating BAT 250.
!
If there is no battery or if the battery voltage is lower
than 1 volt, BAT 250 cannot detect polarity inversal.