  • Page 1 Installation Guide ® Spirent Landslide Test System October 2018 P/N 71-008573 R...
  • Page 2 Software License Agreement, the Software which it supplies will operate in material conformity with the specifications supplied by Spirent for such Software for a period of ninety (90) days from the date of delivery (the “Software Warranty Period”). The “Product Warranty Period” shall mean the Hardware Warranty Period or the Software Warranty Period, as applicable.
  • Page 3 Spirent’s Limited Warranty and which is returned to Spirent with a copy of your proof of purchase. If Spirent is unable to correct such failure, or unable to deliver replacement media which is free from defects in materials or workmanship, you may terminate this Agreement in accordance with the...
  • Page 4 Administration Regulations of the United States Department of Commerce with regard to the exportation of the Software and Documentation. (3) This Agreement is the entire agreement between you and Spirent and supersedes any prior or contemporaneous agreements or communications, oral or written, relating to the subject matter of this Agreement.
  • Page 5: Table Of Contents

    Adding Test Servers to the System ..........47 Spirent Landslide Test System Installation Guide...
  • Page 6 Supported NIC Configurations and Port Names ........52 Spirent Landslide Test System Installation Guide...
  • Page 7: About This Guide

    • Related Documentation ..8 • Shipment Contents ..10 • Release Notes ..10 • How to Contact Us ..11 Spirent Landslide Test System Installation Guide...
  • Page 8: Introduction

    Log in with your CSC user ID and password to access content that is available only to customers - user manuals, help files, release notes, and more. Information about Spirent Communications and its products and services is available on the company website at https://www.spirent.com. Spirent Landslide Test System Installation Guide...
  • Page 9: Acronyms

    Landslide C50 S4 System Appliance L-C50-S4-TS Landslide C50 S4 Add-on Test Server Manager Test Administration Server Appliance SPT-C100-M4-TS Same as L-C100-M4-TS System Under Test Test Administration Server Test Server vTAS Virtual Test Administration Server Virtual Test Server Spirent Landslide Test System Installation Guide...
  • Page 10: Shipment Contents

    C50 Test System). EDGE E10 System Check your system to ensure that you have the following items: • 1 - Landslide EDGE E10 appliance • 1 - Power supply and cord • 3 - Dual-band (2.4 and 5.8GHz) antennas •...
  • Page 11: How To Contact Us

    About this Guide How to Contact Us How to Contact Us To obtain technical support for any Spirent Communications product, please contact our Support Services department using any of the following methods: Americas E-mail: support@spirent.com Web: https://support.spirent.com Toll Free: +1 800-SPIRENT (+1 800-774-7368) (North America)
  • Page 12 Spirent Landslide Test System Installation Guide...
  • Page 13: Chapter 1: System Overview

    Help documentation. In this chapter... • Deployment ..14 • Landslide Architecture Terminology ..15 • Client Requirements ..15 Spirent Landslide Test System Installation Guide...
  • Page 14: Deployment

    System Overview Deployment Deployment Landslide C100 Test System The Landslide C100 Test System is deployed on Spirent Landslide C100 rack-mounted server platforms. A typical lab deployment configuration is shown in Figure 1-1. The Landslide Manager hosts the Test Administration Server (TAS) software, which serves the user interface through the LAN, acts as the data repository, and controls overall system operations.
  • Page 15: Landslide Architecture Terminology

    Help documentation. Select Getting Started > System Overview > Architecture. Client Requirements Hardware and software system requirements are described in the Release Notes. Important: It is highly recommended that you read all Release Notes before you install or use this product. Spirent Landslide Test System Installation Guide...
  • Page 16 Spirent Landslide Test System Installation Guide...
  • Page 17: Chapter 2: Initial Installation

    Initial Installation This chapter provides configuration instructions for the Landslide Performance Test System. In this chapter... • Standard Landslide System Configuration ..18 • Management Port Configuration ..20 Spirent Landslide Test System Installation Guide...
  • Page 18: Standard Landslide System Configuration

    “Landslide Manager Configuration” on page Configure each Test Server by following the steps in “Landslide Test Server Configuration” on page After you have configured your Test Servers, continue with the instructions in Chapter 5, “Getting Started.” Spirent Landslide Test System Installation Guide...
  • Page 19: Landslide Manager Configuration

    Supported NIC configurations and associated port naming are provided in Appendix A. As viewed from the front, chassis slot numbers increase from left to right. The leftmost slot is number 1. Spirent Landslide Test System Installation Guide...
  • Page 20: Management Port Configuration

    (Landslide Test Server platform) or with the user's client PC (Landslide Manager platform), and is not used for testing on these platforms. The default name and default address of the management port is eth0 and 192.168.0.100, respectively. Use a default mask of 255.255.255.0. Spirent Landslide Test System Installation Guide...
  • Page 21 Do not use arrow keys or the Delete key to correct data entry errors; instead, use only the Backspace key. If errors are detected after data has already been entered, at the end of the script, answer no to the reboot question and rerun the command. ipcfg Spirent Landslide Test System Installation Guide...
  • Page 22 12 TS Only - If the system being provisioned is a Landslide Test Server, the user will be prompted to configure the TAS IP Address mode for the TAS that the TS will connect to. Otherwise, the following prompt is skipped. Specify static or dynamic, then press Enter to continue. Spirent Landslide Test System Installation Guide...
  • Page 23 14 A time server is defined for every platform. Landslide supports both NTP and PTP. Specify ntp or ptp and press Enter to proceed with Time Sync Protocol configuration. <TAS / TS / TAS+TS> Time Sync Protocol (ntp/ptp) [ntp]: Spirent Landslide Test System Installation Guide...
  • Page 24 Ethernet link may not auto negotiate properly. In this case, power-cycle the Landslide platform after all connections are made. Telnet to the management port from the laptop or workstation. From a command prompt, enter: telnet 192.168.0.100 Spirent Landslide Test System Installation Guide...
  • Page 25 Specify the IPv6 network mask in slash notation - i.e. /64, then press Enter to continue. <port> IPv6 Network Mask []: • Accept the default configuration to enable automatic speed and duplex negotiation by pressing Enter to continue. Auto Negotiate? (yes/no) [yes]: Spirent Landslide Test System Installation Guide...
  • Page 26 PTP IP Mode, then press Enter to continue. PTP Transport Mode (multicast/unicast/hybrid) [multi- cast]: If unicast is selected, configure the PTP Master Clock IP, specify a valid IPv4 address for the PTP Master Clock. PTP Master Clock IP [10.1.1.1]: Spirent Landslide Test System Installation Guide...
  • Page 27 System must be rebooted for these changes to take effect… Reboot now? (yes/no) [yes]: Note: If errors are detected in any of the data entered above, answer no to the reboot question and rerun the command. ipcfg Spirent Landslide Test System Installation Guide...
  • Page 28 Initial Installation Management Port Configuration Spirent Landslide Test System Installation Guide...
  • Page 29: Chapter 3: Landslide E10 System Overview

    Landslide E10 Test System ..30 • Deployment ..30 • System Configuration Overview ..32 • Federal Communication Commission Interference Statement ..33 Spirent Landslide Test System Installation Guide...
  • Page 30: Landslide E10 Test System

    (1) management interface as shown in the following figures. Three (3) WiFi RF antenna connectors are provided to attach the antennas included in the shipment. Eth2 Test Port Power Button Figure 3-1. Landslide E10 Front View Spirent Landslide Test System Installation Guide...
  • Page 31 Landslide E10 System Overview Deployment Eth1 Test Port Management Port Figure 3-2. Landslide E10 Rear View WiFi RF Antenna SMA Connectors Figure 3-3. Landslide E10 Side View Spirent Landslide Test System Installation Guide...
  • Page 32: System Configuration Overview

    “Landslide Manager Configuration” on page Configure each Test Server using the steps in “Landslide Test Server Configuration” on page After you have configured your Test Server, continue with the instructions in Chapter 5, “Getting Started.” Spirent Landslide Test System Installation Guide...
  • Page 33: Federal Communication Commission Interference Statement

    This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. Spirent Landslide Test System Installation Guide...
  • Page 34 The equipment must not be co-located or operating in conjunction with any other antenna or transmitter. For the 802.11AC version: Contains Transmitter Module FCC ID: TK4WLE900VX For the 802.11n version: Contains Transmitter Module FCC ID: RYK-WPEA128N Spirent Landslide Test System Installation Guide...
  • Page 35: Chapter 4: Installing U1 Ota Modules On The Landslide E10

    E10 carrier and connecting to the E10. In this chapter... • Introduction ..36 • Before You Begin ..36 • Connecting the Antennas ..42 Spirent Landslide Test System Installation Guide...
  • Page 36: Introduction

    “Federal Communication Commission Interference Statement” Important: • for important information pertaining to RF transmitters. • It is highly recommended that you review all Release Notes before you install or use the Landslide E10 appliance and OTA Modules. Spirent Landslide Test System Installation Guide...
  • Page 37: Sim Card Insertion And Removal

    It will disengage the retention spring and release the SIM card. Note: The SIM card release is under spring tension; use care when removing the cards. Figure 4-1. SIM Card Insertion and Removal Spirent Landslide Test System Installation Guide...
  • Page 38: Installing And Removing The Modules

    Before You Begin Installing and Removing the Modules To install the U1 OTA module on the Landslide E10: Remove the Spirent Landslide-branded cover of the E10 Appliance. Use your finger or a small flat-head screwdriver to pry the top cover off.
  • Page 39 Figure 4-4. Insert Module Slide in other modules. Each E10 with top plate can accommodate up to four U1 OTA modules. All antenna ports and mini- USB ports must be facing outward. Figure 4-5. Adding Additional Modules Spirent Landslide Test System Installation Guide...
  • Page 40: Connecting The Usb Cables And Antennas

    Use long USB cables for modules furthermost from the E10 rear I/O panel USB ports Use short USB cables for modules closest to the E10 rear I/O panel USB ports Figure 4-7. Connect USB Cables Spirent Landslide Test System Installation Guide...
  • Page 41 USB port, U1 OTA 1/Port1, OTA2/Port 2, etc. Route the long USB cables using cable ties in between modules. Loop the long USB cables above the antennas to prevent accidental pulling. Figure 4-10. Long USB Cable Placement - step 1 Spirent Landslide Test System Installation Guide...
  • Page 42: Connecting The Antennas

    Insert each antenna into the SMA connectors on the side of the module. connectors Grip the antenna nut, rotate and tighten, to secure the antennas to the module. Secure the antennas to the module Spirent Landslide Test System Installation Guide...
  • Page 43 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The equipment must not be co-located or operating in conjunction with any other antenna or transmitter. For the U1 LTE OTA Module: Contains Transmitter Module FCC ID: N7NMC7455 Spirent Landslide Test System Installation Guide...
  • Page 45: Chapter 5: Getting Started

    Logging in to the System ..46 • Adding Test Servers to the System ..47 • Installing the Tcl API ..47 • Logging in to the System ..46 Spirent Landslide Test System Installation Guide...
  • Page 46: Logging In To The System

    • You must accept the EULA to access and use Landslide. • Refer to the Managing Your System > About System Management online Help topic for information about preparing the system for test operations. Spirent Landslide Test System Installation Guide...
  • Page 47: Adding Test Servers To The System

    The default password for the cfguser account is cfguser Important: If you change the passwords to your system, be sure to record them in a secure location. The passwords are encrypted in the system memory, and Spirent cannot recover them for you.
  • Page 48 Spirent Landslide Test System Installation Guide...
  • Page 49: Appendix A: Landslide Test Server Nic Configurations

    Landslide Test Server NIC Configurations This appendix contains important information regarding your shipment of Spirent Landslide compatible network interface cards (NICs). Landslide Test System test ports are located on the C100 Test Server, the C50 combined Manager and Test Server, or the C50 Add-on Test Server.
  • Page 50: General

    FPGA M2, C100-M4 L-NIC-66 Quad-port, 10 10 GbE, SFP+ 10GBASE-SR 850 C50-S4, C100- Table A-3 through Gbps SFP+ nm MMF M2, C100-M4 Table A-6 Ethernet server (M2 Only: adaptor Table A-11 & Table A-12) Spirent Landslide Test System Installation Guide...
  • Page 51 Card L-ACC-6002 Optical SFP+ 10GBASE-LR 1310nm, L-NIC-66 only Transceiver SFP+ single mode fiber transceiver 10GBASE-LR, SMF 1310NM L-ACC-6004 Optical QSFP+ 40GBASE-LR4 1310 nm, L-NIC-74 only Transceiver single mode fiber transceiver QSFP+ 40GBASE-LR4, SMF 1310NM Spirent Landslide Test System Installation Guide...
  • Page 52: Supported Nic Configurations And Port Names

    The L-NIC-66 is only supported in the C50-S4 and C100-M2/M4 test Warnings: • server models. Any attempt to operate the L-NIC-66 in any unsupported configuration or appliance will void the factory warranty and can result in unexpected behavior and damage to the host appliance. Spirent Landslide Test System Installation Guide...
  • Page 53 Notes: • • L-ACC-007 is optional for all C50-S4 and C100-M4 configurations • C100-M4 test servers support one or two L-ACC-007 IPSec accelerator cards; contact Spirent Customer Support for information about supported configurations (refer to page 11 for contact details). •...
  • Page 54 First quad-port, 1 Gbps eth6, eth7, eth8, eth9 Third quad-port, 1 Gbps eth14, eth15, eth16, eth17 Second quad-port, 1 Gbps eth10, eth11, eth12, eth13 Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
  • Page 55 First quad-port, 1 Gbps eth6, eth7, eth8, eth9 Second quad-port, 1 Gbps eth14, eth15, eth16, eth17 Second quad-port 10 Gbps (L-NIC-66) eth10, eth11, eth12, eth13 Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
  • Page 56 Second dual-port 25/40 GbE NIC (L-NIC- eth4, eth5 73/-74) Fourth dual-port 25/40 GbE NIC (L-NIC- eth8, eth9 73/-74) Third dual-port 25/40 GbE NIC (L-NIC- eth6, eth7 73/-74) Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
  • Page 57 73/-74) First quad-port, 1 Gbps eth4, eth5, eth6, eth7 Second quad-port, 1 Gbps eth10, eth11, eth12, eth13 Second dual-port 25/40 GbE NIC (L- eth8, eth9 NIC-73/-74) Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
  • Page 58 First quad-port 10 Gbps (L-NIC-66) eth2, eth3, eth4, eth5 Second quad-port 10 Gbps (L-NIC-66) eth6, eth7, eth8, eth9 Second quad-port, 1 Gbps eth14, eth15, eth16, eth17 Optional L-ACC-006 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
  • Page 59 Second quad-port, 1 Gbps eth8, eth9, eth10, eth11 Dual-port, 10 Gbps (AONIC) eth2, eth3 First quad-port, 1 Gbps eth4, eth5, eth6, eth7 Third quad-port, 1 Gbps eth12, eth13, eth14, eth15 Optional L-ACC-006 IPSec Accelerator Spirent Landslide Test System Installation Guide...
  • Page 60 First quad-port, 1 Gbps eth6, eth7, eth8, eth9 First dual-port, 10 Gbps eth2, eth3 (AONIC) Second dual-port, 10 Gbps eth4, eth5 (AONIC) Second quad-port, 1 Gbps eth10, eth11, eth12, eth13 Optional L-ACC-006 IPSec Accelerator Spirent Landslide Test System Installation Guide...
  • Page 61 Ports Third dual-port, 10 Gbps eth6, eth7 (AONIC) First dual-port, 10 Gbps eth2, eth3 (AONIC) Second dual-port, 10 Gbps eth4, eth5 (AONIC) First quad-port, 1 Gbps eth8, eth9, eth10, eth11 Optional L-ACC-006 IPSec Accelerator Spirent Landslide Test System Installation Guide...