Summary of Contents for Spirent Landslide EDGE E10
Page 1
Installation Guide ® Spirent Landslide Test System October 2018 P/N 71-008573 R...
Page 2
Software License Agreement, the Software which it supplies will operate in material conformity with the specifications supplied by Spirent for such Software for a period of ninety (90) days from the date of delivery (the “Software Warranty Period”). The “Product Warranty Period” shall mean the Hardware Warranty Period or the Software Warranty Period, as applicable.
Page 3
Spirent’s Limited Warranty and which is returned to Spirent with a copy of your proof of purchase. If Spirent is unable to correct such failure, or unable to deliver replacement media which is free from defects in materials or workmanship, you may terminate this Agreement in accordance with the...
Page 4
Administration Regulations of the United States Department of Commerce with regard to the exportation of the Software and Documentation. (3) This Agreement is the entire agreement between you and Spirent and supersedes any prior or contemporaneous agreements or communications, oral or written, relating to the subject matter of this Agreement.
Log in with your CSC user ID and password to access content that is available only to customers - user manuals, help files, release notes, and more. Information about Spirent Communications and its products and services is available on the company website at https://www.spirent.com. Spirent Landslide Test System Installation Guide...
Landslide C50 S4 System Appliance L-C50-S4-TS Landslide C50 S4 Add-on Test Server Manager Test Administration Server Appliance SPT-C100-M4-TS Same as L-C100-M4-TS System Under Test Test Administration Server Test Server vTAS Virtual Test Administration Server Virtual Test Server Spirent Landslide Test System Installation Guide...
C50 Test System). EDGE E10 System Check your system to ensure that you have the following items: • 1 - Landslide EDGE E10 appliance • 1 - Power supply and cord • 3 - Dual-band (2.4 and 5.8GHz) antennas •...
About this Guide How to Contact Us How to Contact Us To obtain technical support for any Spirent Communications product, please contact our Support Services department using any of the following methods: Americas E-mail: support@spirent.com Web: https://support.spirent.com Toll Free: +1 800-SPIRENT (+1 800-774-7368) (North America)
Page 12
Spirent Landslide Test System Installation Guide...
Help documentation. In this chapter... • Deployment ..14 • Landslide Architecture Terminology ..15 • Client Requirements ..15 Spirent Landslide Test System Installation Guide...
System Overview Deployment Deployment Landslide C100 Test System The Landslide C100 Test System is deployed on Spirent Landslide C100 rack-mounted server platforms. A typical lab deployment configuration is shown in Figure 1-1. The Landslide Manager hosts the Test Administration Server (TAS) software, which serves the user interface through the LAN, acts as the data repository, and controls overall system operations.
Help documentation. Select Getting Started > System Overview > Architecture. Client Requirements Hardware and software system requirements are described in the Release Notes. Important: It is highly recommended that you read all Release Notes before you install or use this product. Spirent Landslide Test System Installation Guide...
Page 16
Spirent Landslide Test System Installation Guide...
Initial Installation This chapter provides configuration instructions for the Landslide Performance Test System. In this chapter... • Standard Landslide System Configuration ..18 • Management Port Configuration ..20 Spirent Landslide Test System Installation Guide...
“Landslide Manager Configuration” on page Configure each Test Server by following the steps in “Landslide Test Server Configuration” on page After you have configured your Test Servers, continue with the instructions in Chapter 5, “Getting Started.” Spirent Landslide Test System Installation Guide...
Supported NIC configurations and associated port naming are provided in Appendix A. As viewed from the front, chassis slot numbers increase from left to right. The leftmost slot is number 1. Spirent Landslide Test System Installation Guide...
(Landslide Test Server platform) or with the user's client PC (Landslide Manager platform), and is not used for testing on these platforms. The default name and default address of the management port is eth0 and 192.168.0.100, respectively. Use a default mask of 255.255.255.0. Spirent Landslide Test System Installation Guide...
Page 21
Do not use arrow keys or the Delete key to correct data entry errors; instead, use only the Backspace key. If errors are detected after data has already been entered, at the end of the script, answer no to the reboot question and rerun the command. ipcfg Spirent Landslide Test System Installation Guide...
Page 22
12 TS Only - If the system being provisioned is a Landslide Test Server, the user will be prompted to configure the TAS IP Address mode for the TAS that the TS will connect to. Otherwise, the following prompt is skipped. Specify static or dynamic, then press Enter to continue. Spirent Landslide Test System Installation Guide...
Page 23
14 A time server is defined for every platform. Landslide supports both NTP and PTP. Specify ntp or ptp and press Enter to proceed with Time Sync Protocol configuration. <TAS / TS / TAS+TS> Time Sync Protocol (ntp/ptp) [ntp]: Spirent Landslide Test System Installation Guide...
Page 24
Ethernet link may not auto negotiate properly. In this case, power-cycle the Landslide platform after all connections are made. Telnet to the management port from the laptop or workstation. From a command prompt, enter: telnet 192.168.0.100 Spirent Landslide Test System Installation Guide...
Page 25
Specify the IPv6 network mask in slash notation - i.e. /64, then press Enter to continue. <port> IPv6 Network Mask []: • Accept the default configuration to enable automatic speed and duplex negotiation by pressing Enter to continue. Auto Negotiate? (yes/no) [yes]: Spirent Landslide Test System Installation Guide...
Page 26
PTP IP Mode, then press Enter to continue. PTP Transport Mode (multicast/unicast/hybrid) [multi- cast]: If unicast is selected, configure the PTP Master Clock IP, specify a valid IPv4 address for the PTP Master Clock. PTP Master Clock IP [10.1.1.1]: Spirent Landslide Test System Installation Guide...
Page 27
System must be rebooted for these changes to take effect… Reboot now? (yes/no) [yes]: Note: If errors are detected in any of the data entered above, answer no to the reboot question and rerun the command. ipcfg Spirent Landslide Test System Installation Guide...
Page 28
Initial Installation Management Port Configuration Spirent Landslide Test System Installation Guide...
Landslide E10 Test System ..30 • Deployment ..30 • System Configuration Overview ..32 • Federal Communication Commission Interference Statement ..33 Spirent Landslide Test System Installation Guide...
(1) management interface as shown in the following figures. Three (3) WiFi RF antenna connectors are provided to attach the antennas included in the shipment. Eth2 Test Port Power Button Figure 3-1. Landslide E10 Front View Spirent Landslide Test System Installation Guide...
Page 31
Landslide E10 System Overview Deployment Eth1 Test Port Management Port Figure 3-2. Landslide E10 Rear View WiFi RF Antenna SMA Connectors Figure 3-3. Landslide E10 Side View Spirent Landslide Test System Installation Guide...
“Landslide Manager Configuration” on page Configure each Test Server using the steps in “Landslide Test Server Configuration” on page After you have configured your Test Server, continue with the instructions in Chapter 5, “Getting Started.” Spirent Landslide Test System Installation Guide...
This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. Spirent Landslide Test System Installation Guide...
Page 34
The equipment must not be co-located or operating in conjunction with any other antenna or transmitter. For the 802.11AC version: Contains Transmitter Module FCC ID: TK4WLE900VX For the 802.11n version: Contains Transmitter Module FCC ID: RYK-WPEA128N Spirent Landslide Test System Installation Guide...
E10 carrier and connecting to the E10. In this chapter... • Introduction ..36 • Before You Begin ..36 • Connecting the Antennas ..42 Spirent Landslide Test System Installation Guide...
“Federal Communication Commission Interference Statement” Important: • for important information pertaining to RF transmitters. • It is highly recommended that you review all Release Notes before you install or use the Landslide E10 appliance and OTA Modules. Spirent Landslide Test System Installation Guide...
It will disengage the retention spring and release the SIM card. Note: The SIM card release is under spring tension; use care when removing the cards. Figure 4-1. SIM Card Insertion and Removal Spirent Landslide Test System Installation Guide...
Before You Begin Installing and Removing the Modules To install the U1 OTA module on the Landslide E10: Remove the Spirent Landslide-branded cover of the E10 Appliance. Use your finger or a small flat-head screwdriver to pry the top cover off.
Page 39
Figure 4-4. Insert Module Slide in other modules. Each E10 with top plate can accommodate up to four U1 OTA modules. All antenna ports and mini- USB ports must be facing outward. Figure 4-5. Adding Additional Modules Spirent Landslide Test System Installation Guide...
Use long USB cables for modules furthermost from the E10 rear I/O panel USB ports Use short USB cables for modules closest to the E10 rear I/O panel USB ports Figure 4-7. Connect USB Cables Spirent Landslide Test System Installation Guide...
Page 41
USB port, U1 OTA 1/Port1, OTA2/Port 2, etc. Route the long USB cables using cable ties in between modules. Loop the long USB cables above the antennas to prevent accidental pulling. Figure 4-10. Long USB Cable Placement - step 1 Spirent Landslide Test System Installation Guide...
Insert each antenna into the SMA connectors on the side of the module. connectors Grip the antenna nut, rotate and tighten, to secure the antennas to the module. Secure the antennas to the module Spirent Landslide Test System Installation Guide...
Page 43
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The equipment must not be co-located or operating in conjunction with any other antenna or transmitter. For the U1 LTE OTA Module: Contains Transmitter Module FCC ID: N7NMC7455 Spirent Landslide Test System Installation Guide...
Logging in to the System ..46 • Adding Test Servers to the System ..47 • Installing the Tcl API ..47 • Logging in to the System ..46 Spirent Landslide Test System Installation Guide...
• You must accept the EULA to access and use Landslide. • Refer to the Managing Your System > About System Management online Help topic for information about preparing the system for test operations. Spirent Landslide Test System Installation Guide...
The default password for the cfguser account is cfguser Important: If you change the passwords to your system, be sure to record them in a secure location. The passwords are encrypted in the system memory, and Spirent cannot recover them for you.
Page 48
Spirent Landslide Test System Installation Guide...
Landslide Test Server NIC Configurations This appendix contains important information regarding your shipment of Spirent Landslide compatible network interface cards (NICs). Landslide Test System test ports are located on the C100 Test Server, the C50 combined Manager and Test Server, or the C50 Add-on Test Server.
The L-NIC-66 is only supported in the C50-S4 and C100-M2/M4 test Warnings: • server models. Any attempt to operate the L-NIC-66 in any unsupported configuration or appliance will void the factory warranty and can result in unexpected behavior and damage to the host appliance. Spirent Landslide Test System Installation Guide...
Page 53
Notes: • • L-ACC-007 is optional for all C50-S4 and C100-M4 configurations • C100-M4 test servers support one or two L-ACC-007 IPSec accelerator cards; contact Spirent Customer Support for information about supported configurations (refer to page 11 for contact details). •...
Page 54
First quad-port, 1 Gbps eth6, eth7, eth8, eth9 Third quad-port, 1 Gbps eth14, eth15, eth16, eth17 Second quad-port, 1 Gbps eth10, eth11, eth12, eth13 Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
Page 55
First quad-port, 1 Gbps eth6, eth7, eth8, eth9 Second quad-port, 1 Gbps eth14, eth15, eth16, eth17 Second quad-port 10 Gbps (L-NIC-66) eth10, eth11, eth12, eth13 Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
Page 56
Second dual-port 25/40 GbE NIC (L-NIC- eth4, eth5 73/-74) Fourth dual-port 25/40 GbE NIC (L-NIC- eth8, eth9 73/-74) Third dual-port 25/40 GbE NIC (L-NIC- eth6, eth7 73/-74) Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
Page 57
73/-74) First quad-port, 1 Gbps eth4, eth5, eth6, eth7 Second quad-port, 1 Gbps eth10, eth11, eth12, eth13 Second dual-port 25/40 GbE NIC (L- eth8, eth9 NIC-73/-74) Optional L-ACC-007 or L-ACC-008 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
Page 58
First quad-port 10 Gbps (L-NIC-66) eth2, eth3, eth4, eth5 Second quad-port 10 Gbps (L-NIC-66) eth6, eth7, eth8, eth9 Second quad-port, 1 Gbps eth14, eth15, eth16, eth17 Optional L-ACC-006 IPSec Accelerator Unused Spirent Landslide Test System Installation Guide...
Page 59
Second quad-port, 1 Gbps eth8, eth9, eth10, eth11 Dual-port, 10 Gbps (AONIC) eth2, eth3 First quad-port, 1 Gbps eth4, eth5, eth6, eth7 Third quad-port, 1 Gbps eth12, eth13, eth14, eth15 Optional L-ACC-006 IPSec Accelerator Spirent Landslide Test System Installation Guide...
Page 60
First quad-port, 1 Gbps eth6, eth7, eth8, eth9 First dual-port, 10 Gbps eth2, eth3 (AONIC) Second dual-port, 10 Gbps eth4, eth5 (AONIC) Second quad-port, 1 Gbps eth10, eth11, eth12, eth13 Optional L-ACC-006 IPSec Accelerator Spirent Landslide Test System Installation Guide...
Page 61
Ports Third dual-port, 10 Gbps eth6, eth7 (AONIC) First dual-port, 10 Gbps eth2, eth3 (AONIC) Second dual-port, 10 Gbps eth4, eth5 (AONIC) First quad-port, 1 Gbps eth8, eth9, eth10, eth11 Optional L-ACC-006 IPSec Accelerator Spirent Landslide Test System Installation Guide...
Need help?
Do you have a question about the Landslide EDGE E10 and is the answer not in the manual?
Questions and answers