GENERAL DATA
Table 7: Four-Way Ceiling Cassette (3' x 3' TN Frames) Indoor Unit General Data.
Model No.
Cooling Mode Performance
Capacity (Btu/h)
Max. Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Heating Mode Performance
Capacity (Btu/h)
Max. Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Entering Mixed Air
Cooling Max (°F WB)
Heating Min (°F DB)
Unit Data
Refrigerant Type
2
Refrigerant Control
Sound Pressure
dB(A) (H/M/L)
3
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Grill Weight (lbs)
Grill Shipping Weight (lbs)
Communication Cable
(No. x AWG)
4
Fan
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
Piping
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Condensate Line (in., I.D.)
EEV: Electronic Expansion Valve
codes. See page 19 for detailed electrical data.
This unit comes with a dry nitrogen charge.
All capacities are net with a combination ratio between 95-105%.
16
ARNU073TNA4
7,500
144
12 / 15 / 18
8,500
144
12 / 15 / 18
76
59
R410A
EEV
29 / 26 / 24
53.6
66.1
14
21
2 x 18
Turbo
1
459 / 424 / 388
3/8 Flare
5/8 Flare
1
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
ARNU093TNA4
ARNU123TNA4
9,600
144
12 / 15 / 19
14 / 17 / 22
10,900
144
12 / 15 / 19
14 / 17 / 22
76
59
R410A
EEV
29 / 26 / 24
31 / 29 / 26
53.6
66.1
14
21
2 x 18
Turbo
1
Brushless Digitally Controlled / Direct
477 / 424 / 388
494 / 459 / 424
3/8 Flare
3/8 Flare
5/8 Flare
5/8 Flare
1
1
Max. power input is rated at maximum setting value.
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
2
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
3
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
Communication cable between Master ODU to IDUs / HRUs to be 18 AWG, 2-conductor,
4
twisted, stranded, shielded. Ensure the communication cable shield is properly grounded
to the Master ODU chassis only.
Do not ground the ODU to IDUs / HRUs communica-
tion cable at any other point. Wiring must comply with all applicable local and national
codes.
ARNU153TNA4
12,300
15,400
144
144
14 / 17 / 25
13,600
17,100
144
144
14 / 17 / 25
76
76
59
59
R410A
R410A
EEV
EEV
32 / 29 / 26
53.6
53.6
66.1
66.1
14
14
21
21
2 x 18
2 x 18
Turbo
Turbo
1
1
530 / 459 / 424
3/8 Flare
5/8 Flare
1
1