NS8000 Series
Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors
Graphical Display models
Installation Guide
Important (USA, Canada)
The NS Series Network Sensor is intended to provide an input to equipment under normal operating conditions. Where failure or
malfunction of the network sensor could lead to personal injury or property damage to the controlled equipment or other property,
additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or
alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the network sensor.
Le NS Series Network Sensor est destiné à transmettre des données entrantes à un équipement dans des conditions normales
de fonctionnement. Lorsqu'une défaillance ou un dysfonctionnement du network sensor risque de provoquer des blessures ou
d'endommager l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs
de protection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que des systèmes de
supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction d'avertissement ou de protection en
cas de défaillance ou de dysfonctionnement du network sensor.
North American Emissions Compliance
United States
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area may cause harmful interference, in which case the users will be required to correct the
interference at their own expense.
Canada
This Class (B) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la Classe (B) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Mounting
Note:
You can surface mount or wallbox mount the NS Series Network Sensor. For wallbox-mounted installations, mount the
NS Series Network Sensor on a vertically roughed-in wallbox only. Do not attempt to mount the sensor on a horizontally
roughed-in wallbox.
Johnson Controls® does not supply the required hardware to mount the sensors.
72.0
°F
74.5
CO2
40
466
*241144300006RevB*
466
ppm
CO2
40
1
Part No. 24-11443-00006, Rev. B
Issue Date January 2020
72
Part No. 24-11443-00006, Rev. B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NS8000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Johnson Controls NS8000 Series

  • Page 1 NS Series Network Sensor on a vertically roughed-in wallbox only. Do not attempt to mount the sensor on a horizontally roughed-in wallbox. • Johnson Controls® does not supply the required hardware to mount the sensors. Part No. 24-11443-00006, Rev. B...
  • Page 2: Location Considerations

    Special tools (only one type needed) Johnson Controls T-4000-119 Allen-head adjustment tool JC 5309 Allen-head flexible tool 1/16 in (1.5 mm) Allen wrench Part No. 24-11443-00006, Rev. B...
  • Page 3: Installation

    NS8000 Series Installation Risk of Electric Shock. Disconnect the power supply before making electrical connections to avoid electric shock. Risque de décharge électrique. Débrancher l’alimentation avant de réaliser tout raccordement électrique afin d’éviter tout risque de décharge électrique. IMPORTANT: Do not insert tools into the housing. Be careful not to damage any components when pushing the tabs on either side of the sensor.
  • Page 4 NS8000 Series Part No. 24-11443-00006, Rev. B...
  • Page 5 NS8000 Series Graphical display overview 72.0 °F 74.5 Figure 2: Fan speed screen Figure 3: Settings screen Figure 1: Temperature screen Table 1: Display icons Icon Icon name Icon description Hide options Up arrow Increases current setting Down arrow Decreases current setting...
  • Page 6 NS8000 Series Setup and adjustments for the graphical display model Main screens overview The NS8000 Graphical Sensor model features five main display screens. See Table 1 for touchscreen icon descriptions. The current values for temperature, relative humidity (RH), or CO show below the relevant icon.
  • Page 7 NS8000 Series Adjusting the temperature unit Press the Settings icon and use the scroll arrow to navigate to the second page. To change the temperature unit, tap the Toggle icon to switch between Fahrenheit and Celsius. Changing the decimal separator Press the Settings icon and tap the arrow in the top right to navigate to the second page.
  • Page 8: Repair Information

    Repair information If the NS Series Graphical Network Sensor fails to operate within its specifications, replace the unit. For a replacement NS Series Graphical Network Sensor, contact the nearest customer service center or Johnson Controls representative. Part No. 24-11443-00006, Rev. B...
  • Page 9: Technical Specifications

    NS8000 Series Technical specifications Supply voltage 9.8 VDC to 16.5 VDC; 15 VDC nominal (from SA bus) Current consumption Base current Screen off 18 mA maximum (non-transmitting) draw (all Screen on 45 mA maximum models) models 13 mA maximum additional current (during measurement) Note: SA bus applications are limited to a power load of 210 mA.
  • Page 10 The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products.