  • Page 2: Locating The Thermostat

    Once all wires are removed from the existing thermostat wiring terminal, remove the existing thermostat from the wall.  Make sure to leave at least 3” of wire for each connection onto the CentraLite thermostat wiring terminal.  Remove 1/8” insulation from the end of each wire.
  • Page 3 Install CentraLite Thermostat  Place each wire in the appropriate wire terminal. The wiring terminal is labeled as follows: G/G3 W2/G2 W1/B/O Y2/G1 Common Cool G/G3 Fan/High Speed Fan W2/G2 Second Stage Heat/Medium Speed Fan W1/B/O Heat/Changeover Valve Y2/G1 Second Stage Cool/Low Speed Fan...
  • Page 4: Thermostat Configuration

     The CentraLite thermostat can be powered by 4 AA batteries or by the power from the HVAC unit if a Common wire is available. Even if you use the common wire for power you should install 4 AA batteries as a backup for the thermostat time clock.
  • Page 5: Thermostat Overview

    Thermostat Overview Reset Switch Current Temp Wiring Terminal Setpoint Temp Setpoint UP Fan Indicator Zigbee Status Setpoint DOWN 4 AA Batteries...
  • Page 6: Testing Thermostat Operation

    Testing Thermostat Operation  After completing any necessary configuration make sure the thermostat is in Cool mode by pressing the MODE button until Cool is displayed at the bottom of the screen.  Make sure the system is not calling for Cooling by setting the setpoint several degrees above the room temperature. Then check the Fan operation by pressing the Fan button.
  • Page 7 The first step in the join process is to make sure the Zigbee HA controller is in it’s join network mode.  The CentraLite thermostat will attempt to join a Zigbee HA network upon power up or after pressing the Reset button(as long as it has not already been joined to another Zigbee HA network).
  • Page 8: Thermostat Functions

    Thermostat Functions  MODE button cycles between system modes: HEAT/COOL/AUTO/OFF  FAN button toggles between Fan On Mode and Fan Auto Mode. If available it will cycle through multiple fan speeds.  HOLD button will enable Hold function which locks out all scheduled system changes. This includes internal schedules and external schedules from a controller.
  • Page 9: Thermostat Programming

    Thermostat Programming To enter programming mode: PRESS FAN and MODE buttons at the same time. Then press the UP ARROW button.. The clock display will change to indicate which programming mode you’re currently in. The display will start at 10:00. If there is ever any inactivity for more than 30 seconds the thermo- stat will automatically return to normal operation.
  • Page 10 Thermostat Programming 11:10(Type) 1 Heat, 1 Cool(DEFAULT) 1 Heat, 2 Cool 2 Heat, 1 Cool 2 Heat, 2 Cool Heat Pump, Changeover Energized on Heat Heat Pump, Changeover Energized on Cool Heat Pump, Separate B and O Heat Pump, 1 Heat, 2 Cool, Changeover Energized on Cool Heat Pump, 2Heat, 1 Cool, Changeover Energized on Cool Heat Pump, 1 Heat, 2 Cool, Changeover Energized on Cool Heat Pump, 1 Heat, 2 Cool, Changeover Energized on Heat...
  • Page 11 Thermostat Programming 12:21(System Mode) Cooling Only(COOL and OFF modes only) Cooling with Reheat Heating Only(HEAT and OFF modes only) Heating with Reheat Full Mode(AUTO, COOL, HEAT, OFF) Full Mode with Reheat(AUTO, COOL, HEAT, OFF) Manual Mode(COOL, HEAT, OFF) (DEFAULT) Auto Mode(AUTO, OFF) 13:10(Calibration) -09 to 09: Temperature Calibration(DEFAULT = 00) 14:11(Occupancy Differential)
  • Page 12 Thermostat Programming 15:21(Cool Mode Delay) 00-99: Minimum Delay in minutes for change into Cool Mode 15:31(Heat Mode Delay) 00-99: Minimum Delay in minutes for change into Heat Mode 16:11(Temperature Scale) Celsius Fahrenheit 16:21(Minimum Cool Time) 00-99: Minimum Time in Minutes Unit will run during a Cool Cycle 16:31(Minimum Heat Time) 00-99: Minimum Time in Minutes Unit will run during a Heat Cycle...
  • Page 13 Thermostat Programming 17:21(Display Type) Current Temperature Without Decimal Point Current Temperature With Decimal Point Setpoint Temperature Without Decimal Point Setpoint Temperature With Decimal Point 18:11(Cool Setpoint Upper Limit) 00-99: Upper limit of Cool Setpoint 18:21(Cool Setpoint Lower Limit) 00-99: Lower limit of Cool Setpoint 18:31(Heat Setpoint Upper Limit) 00-99: Upper limit of Heat Setpoint...
  • Page 14 Thermostat Programming 21:10(Active Scan and Join Available Network) 22:10(Join Network) 23:10(Leave Network) 24:10(Status) 31:10(Set Clock Day) 32:10(Set Clock Hours) 33:10(Set Clock Minutes) 41:00(Reset) 42:00(Factory Reset) 51:00(Lock Keys) 52:00(Password)
  • Page 15 Notes...
  • Page 16 Consult the dealer or an experienced radio/TV technician for help The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by CentraLite Systems, Inc. may void the user’s authority to operate the equipment. Contact Tech Support at:...