Receptacle Wiring Diagram; Remote Receiver Installation - Napoleon High Definition 81 Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

electrical information
EN
6.4

receptacle wiring diagram

ELECTRICAL BOX
3 PRONGE
RECEPTACLE
(WHITE)
6.5

remote receiver installation

Receiver must be located
within 8 feet (2.4m) of this side
of the appliance and must be
accessible for
programming the remote.
Install the receiver into a
standard electrical switch
box. Determine an
appropriate location and
install the electrical box.
NOTE: Ensure the three
position slider switch is
in the "REMOTE"
position (middle).
36
W415-2362 / A / 10.25.19
NOTE: RECEIVER WIRE IS BUNDLED UP IN THE CONTROL BOX AND
NEEDS TO BE INSTALLED REMOTELY. FOR INSTALLATION SEE
"REMOTE RECEIVER INSTALLATION" SECTION.
(BLACK)
WIRE NUTS
GROUND
(GREEN)
GROUND
(GREEN)
CONTROL
BOX
TO REMOTE RECEIVER
L1 (BLACK)
CABLE
CONNECTOR
SCREW
ELECTRICAL
L2 (WHITE)
BOX COVER