Minimum Clearances To Combustibles; Hearth Extension - Napoleon High Definition 81 Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

framing
EN
4.1

minimum clearances to combustibles

Maintain these minimum clearances to combustibles from appliance and vent surfaces:
Appliance framing:
Use steel stud framing provided.
Non- Combustible Appliance fi nishing:
Front -
7 5/8" (194mm) to sides of appliance opening
-
16 1/16" (40.8cm) to top of appliance opening
Combustible Appliance fi nishing:
-
84" (213cm) from bottom of appliance to enclosure top
-
2" (50.8mm) to top, sides, and bottom of vent pipe*
*HORIZONTAL VENT SECTIONS: A minimum clearance of 2" (50.8mm) all around the vent pipe on all horizontal
runs to combustibles is required except for clearances in appliance enclosures. Horizontal vent sections within
the enclosure require a minimum clearance of 11 5/8" (29.5cm) from the top of the vent pipe, see "MINIMUM
CLEARANCE TO COMBUSTIBLE ENCLOSURES" section. Use fi restop spacer W010-3364 (supplied).
*VERTICAL VENT SECTIONS: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
combustibles is required except for clearances in appliance enclosures. Vertical vent sections within enclosures
require a minimum clearance of 3" (76.2mm) around the vent pipe, see "MINIMUM CLEARANCES TO
COMBUSTIBLE ENCLOSURES" section. Use fi restop spacer W010-3364 (not supplied).
4.2

hearth extension

While a hearth extension is not required for this appliance, one is recommended
for aesthetic reasons. The installation of a 1" (25mm) hearth extension will
conceal the 1" (25mm) gap under the appliance. The hearth extension must
not be any more than 1" (25mm) above the bottom of the appliance.
If thicker, the appliance must be raised up accordingly.
NOTE: Hearth extensions thicker than 1" (25mm) will
interfere with the safety barrier assembly.
24
W415-2362 / A / 10.25.19
MAIN DOOR
SAFETY
BARRIER
ASSEMBLY
1" (25.4mm) MAX
HEARTH
EXTENSION
1/4" (6.4mm)