GD20SS Dehumdifier
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Gemini GD20SS

  • Page 1 GD20SS Dehumdifier User’s Manual...
  • Page 2 Index • Important Safe Guards • • Room Environment For Operating • Components Diagrams • Operating Introduction - Functions of Control Panel & Key Pads - Operation of Key Pads - Automatic Defrosting - Water Full Protect Function - Compressor Stop / Start Working Function - Low &...
  • Page 3: Important Safeguards

    Important Safe Guards Do not install and use the unit before carefully reading this instruction guide.   Please retain this manual for product warranty and future reference. 1)   Please be sure your electricity is 4)   Never operate this unit in an correct.
  • Page 4 Important Safe Guards Important Safe Guards 7)   Do not use the unit when slanted. 10)   D o not spray water on the unit, If toppled over, please pull out spraying water may cause the plug at once. malfunctioning and electric shock.
  • Page 5 Important Safe Guards Important Safe Guards 13)   S witch off and unplug the unit, 15)   N ever put fingers or other objects empty the water reservoir when in any openings of the unit. not using the unit for a long time. 14)...
  • Page 6 Room Environment For Operating 1. Suitable environment temperature is between 5°C to 35°C 2. Operate the unit indoors, e.g. living room, bedroom, etc. Never use it in wet environment or outdoors. 3. Make sure the door and window are closed before turning on the unit. 4.
  • Page 7: Components Diagrams

    Components Diagrams Louver Control panel Handle Removable Filter cover Water tank...
  • Page 8: Operating Introduction

    Operating introduction 1. Functions of Control Panel & Key Pads 1. On/Off: Switch on/off the power. 2. Fan: Pressing the button to set high or low level 3. Set: Pressing the button to set target Room humidity, you can set: 40%RH, 45%RH, 50%RH, 55%RH, 60%RH, 65%RH, 70%RH, 75%RH, 80%RH and continuing operation.
  • Page 9 Operating introduction 2.3 Set: (Pressing this button to set the value from ~40%~45%~50%~55%~60%~ 65%~70%~75%~80%~continuing dehumdifying,circularlly Remark: The humidity just can be set when humdity setting indicator is lighting. • Pressing 1st to make the machine from continuing dehumidifying mode to the 40%RH(target humidity), continuing dehumidifying indicator lamp crushing out and setting indicator lamp lighting up.
  • Page 10 Operating introduction 2.4 Swing button: (controlling the swing confition) • When the machine is working,pressing air-plate to make stepping motor ON/OFF, the corresponding swing indicator lamp light/quenching. Stepping motor turn down(anticlockwise) to make air- plate turn 45°, then turn up(anti-clockwise) to make air-plate turn 45°, then turn down(clockwise) to make air-plate 45°, circularly like this.
  • Page 11 Operating introduction -  When powering on, if the machine has been already set timing powering on time, and then if you set timing powering on time again, the timing will be increased from the data of preset remaining time, and if you don’t set again within 3s, it will turn to indicate timing powering on time, and as times goes by, it will indicate preset remaining time.
  • Page 12 Operating introduction 3. Automatic Defrosting: When machine is working under low-temperature, the evaporator’s surface will defrost, to guarantee machine’s normal operating, the product has defrosting-automatically function. • If the temperature sensor test temperature of evaporator’s copper tube ≤-1℃, compressor will continue working 30 minutes and then it will stop working (product will defrost), the indicator lamp of fan’s high level and defrosting are lighting, other indication keep original condition, after temperature sensor test the temperarure of evaporator’s copper tube ≥2℃...
  • Page 13 Operating introduction 5. Compressor stop/start working function: When the machine is operating,any operation can cause compressor stop working.And machine will turn to protection funtion of compressor stop working 3 minutes and then start up,the other function is normal. If the machine is under dehumidifying or refrigerating,fetching out water tank or switching OFF and then switching ON, interval time should reach 3 minutes, and then machine will start dehumidifying.
  • Page 14: Maintenance And Cleaning

    Maintenance and Cleaning For its casing is made of plastic, do not place it in direct sunlight. Remove the water tank with care. Only use a soft clean cloth for all cleaning purpose. Do not use gasoline, paint thinner or other chemicals to clean the unit. Cleaning mesh filter: Remove the filter in arrow direction (as shown on figures).
  • Page 15: Specification Table

    Specification Table MODEL GD20SS 220-240V RATED VOLTAGE RATED FREQUENCY 50Hz 250W (26.7℃ 60%RH) RATED INPUT CAPACITY 20L/D (30℃ 80%RH) 12L/D (26.7℃ 60%RH) REFRIGERANT R134a(155g) HIGH PRESSURE 1.5MPa LOW PRESSURE 0.4Mpa MAX. PERMITED PRESSURE 1.9MPa...