Watts FloodSafe WDS-SP-L Series Manual
Watts FloodSafe WDS-SP-L Series Manual

Watts FloodSafe WDS-SP-L Series Manual

Water detector shutoff sizes: 3/4" and 1" 20 and 25mm

Advertisement

Quick Links

Series WDS-SP-L, WDS-SP-R
FloodSafe
Water Detector Shutoff
®
Sizes:
" and 1" (20 and 25mm)
3
4
Please read all instructions, identify all components and read all warnings prior to beginning the installation of this product.
This product is intended to prevent catastrophic water damage in the event of a water heater leak.
Please Note: During an emergency operating condition, the temperature and pressure relief valve installed on your water heater can
discharge an excessive amount of water. It is designed to protect your home or business from the potential danger of explosion. Upon
detection of this discharged water, the FloodSafe
(gas, oil or electricity) to the water heater, preventing a very dangerous situation.
The FloodSafe
Water Detector Shutoff also contains an audible & visual alarm and contacts for monitored alarm systems. It is a reset-
®
table device and can be tested at any time to ensure proper operation.

Parts Included

Control Unit
Water Detector Pad
Important Note: Thermostat wiring is required and must be supplied by the installer.

Planning Your Installation:

The Water Detector Shutoff should be installed within 6 to 12 inches of the water heater on the cold water inlet supply pipe.
The Control Unit, which houses the circuitry for the operation of the valve, contains interlocking connectors for the Water Detector Pad,
the Power Supply and remote alarm and the Power Cutout Module. The cables provided should not be cut or extended; therefore,
remote installation is not recommended.
The Water Detector Pad supplied with the Water Detector Shutoff should be located as close to the water heater as possible. It is not
necessary to remove the cover of the Control Unit to install the interconnecting cables.

Flooring Surface:

Dirt fl ooring – A metal or plastic drain pan must be installed under the water heater. Position the Water Detector Pad inside the
drain pan.
Cement fl oor – Install the Water Dam provided with the Water Detector Shutoff installation kit around the outside diameter of the
water heater. Position the Water Detector Pad inside the Water Dam.
Attic installation – A metal or plastic drain pan must be installed under the water heater. Position Water Detector Pad inside the
drain pan.
Standing Pilot Gas Valves
common right-hand thread, Watts has models for each design. Check to be certain that you have the correct model before beginning
your installation.

Models

WDS-SP-L: Left-hand thread
WDS-SP-R: Right-hand thread
Please be certain to follow all local codes when installing this device.
Water Detector Shutoff shuts off both the supply of water and the source of power
®
Power Cutout Module
Pocket Screwdriver
– Thermocouples used on some manufactures' gas valves use a left-hand thread instead of the more
Power Supply
Water Dam
IS-WDS-SP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FloodSafe WDS-SP-L Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Watts FloodSafe WDS-SP-L Series

  • Page 1 Standing Pilot Gas Valves – Thermocouples used on some manufactures' gas valves use a left-hand thread instead of the more common right-hand thread, Watts has models for each design. Check to be certain that you have the correct model before beginning your installation.
  • Page 2 Installation Instructions: a. Turn off all (gas) power to the water heater. b. Turn off the water supply to the water heater. c. Drain water from the water heater so that the cold water supply piping is free of water. d.
  • Page 3 Standing Pilot Operation: 1. Remove the thermocouple from the gas valve. Figure 8 2. Install the Power Cutout Module supplied with the Water Detector Shutoff to the gas valve. Figure 9 3. Install the thermocouple to the Power Cutout Module. Figure 10 Figure 10 Figure 8 Figure 9...
  • Page 4 Water Dam Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.

This manual is also suitable for:

Floodsafe wds-sp-r series

Table of Contents