Installation; Installation Conditions; Outside Dimensions - Sony CNU-500 Installation And Maintenance Manual

Camera command network unit
Hide thumbs Also See for CNU-500:
Table of Contents

Advertisement

1-3. Functions of Switches on AT Board

1-4. Installation

. S6 (SYNC ON/OFF)
Used to specify whether a synchronizing signal is added to
the video signal output from the CHARACTER terminal.
Factory-setting : ON
. S1100 (BAUD RATE SETTING)
SW No.
Setting Position
S1100-2
ON
OFF
S1100-3
OFF
ON
S1100-4
OFF
OFF
S1100-5
OFF
OFF
S1100-6
OFF
OFF
S1100-7
OFF
OFF
S1100-8
OFF
OFF
BAUD RATE 19,200 9,600 4,800 2,400 1,200 600
n
Be sure to set one of these switches to ON.Never set two or
more switches to ON or all switches to OFF.
Factory-setting : 19,200 bps.
S1100-1 : Not used
. S1102 (OPERATION)
NORMAL:
Normal mode
EMERGENCY: When the CNU-500 or master setup unit
does not operate normally, set this switch
to EMERGENCY.The camera can be
controlled by the control panel.
Factory-setting : NORMAL
. D4 (+5 V INDICATOR)
Lights when the +5 Vdc is supplied to the AT-100 board
correctly.
. RV1 (CHARACTER PHASE)
Adjusts the horizontal phase with respect to the reference
signal of the video output from the CHARACTER
terminal.When the monitor is set to external sync signal,
the horizontal position of the CHARACTER can be
adjusted.
1-4 (E)
OFF
OFF
OFF
OFF OFF
OFF
OFF
OFF
OFF OFF
ON
OFF
OFF
OFF OFF
OFF
ON
OFF
OFF OFF
OFF
OFF
ON
OFF OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF ON
300
Unit : bps
1-4. Installation

1-4-1. Installation Conditions

Operating temperature
: +5dC to +40dC
: _20dC to +50dC
Storage temperature
Humidity
: No condense
Power sources
: AC 100 V to 120 V(UC)
Power frequency
: 50/60 Hz
Power consumption
: 4 A (MAX):UC
. Install the unit in a location as dry and well-ventilated as
possible.
. Do not install the unit in the following conditions.
High temperature room or near the heat source
Excessive dust or mechanical vibration
Intense magnetic and electric fields
A place subjected to direct sunlight or strong light

1-4-2. Outside Dimensions

POWER
424
465
482
AC 110 V to 120 V/ AC 220 V
to 240 V(CE)
2.5 A (MAX):CE
CAMERA COMMAND NETWORK UNIT
(Unit : mm)
CNU-500

Advertisement

Table of Contents
loading

Table of Contents