8 Parameter mode
−26−
Use
to navigate
through the items.
AWO contact configuration
Hardware overtravel
detection
LS contact configuration
HOMES contact
configuration
SLIT contact
configuration
Overtravel action
Preset position
Area 1
Area 2
Encoder counter
preset value
START input mode
Initial
Setting range
value
0
0: Make (N.O.)
1: Brake (N.C.)
1
0: Disable
1: Enable
0
0: Make (N.O.)
1: Brake (N.C.)
0
0: Make (N.O.)
1: Brake (N.C.)
0
0: Make (N.O.)
1: Brake (N.C.)
0
0: Immediate
stop
1: Decelerate
stop
0
−8,388,608 to
+8,388,607
steps
0
−8,388,608 to
+8,388,607
steps
0
−8,388,608 to
+8,388,607
steps
0
−8,388,608 to
+8,388,607
steps
Description
Sets the AWO input logic.
Sets whether to enable or
disable hardware
overtravel detection using
LS inputs.
Sets the ±LS input logics.
Sets the HOMES input
logic.
Sets the SLIT input logic.
Sets the motor action to
take place upon the
occurrence of overtravel.
Sets the preset position.
Sets the range for AREA
output. The AREA output
will be ON when the motor
is inside the area set by the
Area 1 and Area 2.
Sets the encoder counter
preset value.