Section
Dimensions
Car data
Page 2
Width
dimensions
Page 3
Width
dimensions
Page 4
Function
Approach
Load per
parking sp.
Page 5
Load plan
Page 6
Pit edge
Page 7
Electrical
installation
Technical
data
Page 8
Tec. data
100
To be perfor-
[3' - 3'']
med by the
customer
Page 9
Description
U20 EB-425 [13'-11'']
Type
U20 EB-425 [13'-11'']
Standard type
1
Special system: maximum load for extra charge.
2
To follow the minimum finished dimensions, make sure
3
to consider the tolerances according to VOB, part C
(DIN 18330 and 18331) and the DIN 18202.
Car width for platform width 230 cm [7'-7'']. If wider
4
platforms are used it is also possible to park wider cars.
Potential equalization from foundation grounding connection
5
to system (provided by the customer).
Slope with drainage channel and sump see page 6.
6
In compliance with DIN EN 14010, 10 cm [4''] wide yellow-black
7
markings compliant to ISO 3864 must be applied by the
customer to the edge of the pit in the entry area to mark the
danger zone (see „load plan" page 5).
Pit edge see page 6.
8
At the transition section between pit floor and walls no hollow
9
mouldings/coves are possible. If hollow mouldings/coves are
required, the systems must be designed smaller or the pits
accordingly wider.
10
5
Grounding
Water drainage
70
[2' - 4'']
x
530 [17'-5''] for vehicle up to 5.00 m [16'-5''] long
(550 [18'-1''] for vehicle up to 5.20 m [17'-1''] long)
car height
165 [5'-5'']
KLAUS Multiparking GmbH
Hermann-Krum-Straße 2
D-88319 Aitrach
Fon +49 (0 ) 75 65 5 08-0
Fax +49 (0 ) 75 65 5 08-88
info@multiparking.com
www.multiparking.com
11
8
6
70
[2' - 4'']
U20 EB-495 [16'-3'']
Type
car height
U20 EB-495 [16'-3'']
200 [6'-7'']
Security fences are mounted in the side and rear area,
10
under certain structural conditions these can be dispensed
with. This requires consultation with KLAUS Multiparking.
The upper platform is a frame construction. Flooring can
11
be provided by the customer (e.g. soil/turf, sandbed/turfblock,
sandbed/marble, etc.). Maximum weight of customer coating
250 kg / m
The upper platform is at ground level and is traversible when
in lowered position (vehicle load: 2600 kg [5730 lbs] maximum,
wheel load: 650 kg [1430 lbs] maximum). On special conditions
the upper platform may be used as parking space.
A separate shaft for maintenance is required on site (with
12
shaft covering, shaft ladder and passage to the pit). Access
to the shaft for maintenance must be secured on site – this
requires consultation with KLAUS Multiparking. The hydraulic
unit is also housed in the shaft for maintenance.
Snow load data for system in lowered position see page 4.
13
After operation, the system must always be run into the
lowest final position (key interlock).
PRODUCT DATA
2000 kg [4400 lbs]
2600 kg [5730 lbs]
Dimensions
All space requirements are minimum
finished dimensions.
7
Tolerances for space
requirements
+ 3
EB (single platform) = 2 + 1 vehicles
Dimensions: cm [ft]
Weights:
kg [lbs] (1 kg = 2.2 lbs)
Forces:
kN [lbf] (1 kN = 224.8 lbf)
Temperature: °C [°F]
Suitable for
Standard passenger cars:
Limousine, Station Wagon, SUV, Van
according to clearance and maximum
surface load.
9
Standard
Width
190 cm [6'-3'']
Weight
Wheel load
Clearance profile
160 [5'-3'']
15°
100
[3'-3'']
Environmental conditions
Wind zone 3 from 0.47 kN / m
[9.8 lbf / ft
] in accordance with
2
DIN EN 1991-1-4.
Snow load zone 3 from 6.86 kN / m
[143 lbf / ft
] in accordance with
2
DIN EN 1991-1-3.
[5933 lbs/ ft
].
2
2
U20 EB
1
2
+ 1''
3
[ ]
0
0
(1 cm = 0,393 in)
(0° C = 32° F)
2
Special
4
4
190 cm [6'-3'']
see page 4
see page 4
30
[12'']
13°
125
[4'-1'']
500 (520)
[16'-5'' (17'-1'')]
13
2
2

Advertisement

loading
Need help?

Need help?

Do you have a question about the multibase U20 EB Series and is the answer not in the manual?

Questions and answers

Summary of Contents for KLAUS Multiparking multibase U20 EB Series

  • Page 1 Security fences are mounted in the side and rear area, under certain structural conditions these can be dispensed Special system: maximum load for extra charge. with. This requires consultation with KLAUS Multiparking. To follow the minimum finished dimensions, make sure The upper platform is a frame construction. Flooring can to consider the tolerances according to VOB, part C be provided by the customer (e.g.
  • Page 2 Page 2 of 9 MultiBase U20 EB | Code number 588.51.740-003 | Version 04.2019 Width dimensions – Single platform (EB) and Serial system (with dividing walls) Page 1 Section Top view closed pit Dimensions Car data Single platform (EB) Serial system (with dividing walls) Page 2 Shaft covering Shaft covering...
  • Page 3 Page 3 of 9 MultiBase U20 EB | Code number 588.51.740-003 | Version 04.2019 Width dimensions – 2 x Single platform (without dividing walls) Page 1 Section Top view closed pit Dimensions Car data 2 x Single platform (without dividing wall) Page 2 Shaft covering Width...
  • Page 4 Page 9 Description The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking accepts no responsibility. Load per parking space...
  • Page 5 Page 5 of 9 MultiBase U20 EB | Code number 588.51.740-003 | Version 04.2019 Load plan Page 1 Section Section Dimensions Car data Page 2 Entrance Width dimensions Page 3 Width dimensions Page 4 Function Approach Top view Load per parking sp.
  • Page 6 Page 6 of 9 MultiBase U20 EB | Code number 588.51.740-003 | Version 04.2019 Pit edge / Drainage Page 1 Section Dimensions Car data Entrance Circular drainage Page 2 channel Width dimensions Page 3 Width dimensions Floor drain Page 4 Function Approach Load per...
  • Page 7: Electrical Installation

    Stand for operating device 1 per Technical system data Electrical data (included in delivery of KLAUS Multiparking) Page 8 Tec. data Description To be perfor- Control box with lockable main switch med by the customer Control line 3 x 0.75 mm...
  • Page 8 – Sound protection package according to offer/order Table 9 shows the values for the maximum permissible A-rated (KLAUS Multiparking GmbH) sound levels in rooms requiring external protection, generated – Minimum sound insulation of the building of min. R’ w = 62 dB by technical domestic installations and business affiliated with...
  • Page 9 We reserve the right to change this specification without further notice Description KLAUS Multiparking reserves the right in the course of technical progress to use newer or other technologies, systems, processes, procedures or standards in the fulfillment of their obligations other than those originally offered provided the customer derives no...