Troubleshooting - Eastwood 21285 Instructions Manual

Electric drill
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
Does Not Run
When Trigger
is Depressed
Motor Runs
Too Slow/
Develops Low
Power
Excessive
Noise and/or
Vibration
Motor
Overheats
10
CAUSE
No Electric
Power to Drill
Undersized or
Too Long of an
Extension Cord
Drill Bit or
Accessory is
Damaged
Excessive
Pressure Being
Applied to
Drill Bit
Dirt and Debris
Buildup in
Motor Cooling
Air Slots
Eastwood Technical Assistance: 800.343.9353 >> techelp@eastwood.com
CORRECTION
Check 120 VAC input plug connection.
Check for tripped circuit breaker.
Use only 16 gauge or larger cord.
Limit length to 25'
WARNING: This is an extremely dangerous
Stop use and replace bit or accessory!
condition!
Allow the rotating Bit do the drilling.
Do Not force!
Use a brush or compressed air to remove debris.