5
OPTIONAL MODULES
The system can be equipped either with an ETI or Dual LAN interface module.
5.1
ETI Module
The optional ETI Module (ID: 470100) offers one ETI output and one ETI input as
well as one 2.048 MHz clock in-/output.
Table 5: ETI Input
Pin
Signal
Description
1
DATA IN
ETI In
2
GND
Ground
Table 6: ETI Output
Pin
Signal
Description
1
DATA OUT
ETI Out
2
GND
Ground
Table 7: Clock In-/Output (programmable)
Pin
Signal
Description
1
CLK
2.048 MHz Clock
2
GND
Ground
PAGE 19
Electrical characteristics
Socket:
BNC, female
Amplitude:
3 Vpp/G.703
75 Ω unbalanced
Impedance:
Max. cable length: 100 m
Electrical characteristics
Recommended cable: CAT5 or
Socket:
BNC, female
higher
Amplitude:
3 Vpp/G.703
Max. cable length: 100m
75 Ω unbalanced
Impedance:
Max. cable length: 100 m
Recommended cable: CAT5 or higher
Max. cable length: 100m
Electrical characteristics
Socket:
BNC, female
Amplitude:
0.5 ... 1.9 V0p In
1.5 V0p Out
75 Ω unbalanced
Impedance:
Max. cable length: 100 m
Recommended cable: CAT5 or
higher
Max. cable length: 100m