Putting Magic Dabmux Plus Into Operation; Mounting; Connection To The Main Voltage - AVT MAGIC DABMUX plus Hardware Manual

Dab/dab+ ensemble multiplexer
Hide thumbs Also See for MAGIC DABMUX plus:
Table of Contents

Advertisement

2

PUTTING MAGIC DABMUX PLUS INTO OPERATION

2.1

Mounting

With its dimensions (W  H  D) of 430 mm  44,45 mm (1 U)  225 mm the
MAGIC DABMUX plus system can be used either as desktop device or mounted
in 19-inch racks. Mounting brackets are included in the scope of delivery.
When mounting the unit please keep in mind that the bending radius of the
connected cables is always greater than the minimum allowed value.
Although the system has an integrated fan for proper cooling, it is recommended
to have sufficient ventilation. The ambient temperature of the system should be
within the range of +5C and +45C. This threshold is specially to observe if the
system is inserted in a rack.
The temperature of the system can be displayed via the System Monitor of the
web interface.
During operation humidity must range between 5% and 85%.
Incorrect ambient temperature and humidity can cause functional deficiencies.
Operation outside the threshold values indicated above leads to a loss of
warranty claim.
2.2

Connection to the main voltage

The system can be operated with mains voltage in the range of 100V and 230V
AC. The mains frequency can range from 45 Hz to 65 Hz. The maximum power
consumption is 30W.
After switching on the system, the unit boots in a few seconds.
PAGE 11