Drain Piping; Wiring Connection - LG MULTI V Installation Manual

Hide thumbs Also See for MULTI V:
Table of Contents

Advertisement

Drain Piping

1. To remove the front panel from the indoor unit,
remove the front panel from the indoor unit
cabinet.
■ Set the air direction louvers up-and-down to the
position(horizontally) by hand.
■ Remove the securing screws that retain the front
panel. Pull the lower left and right sides of the
grille toward you and lift it off.
(2.1/7, 2.6/9, 3.5/12 kW/Btu models: 2EA,
3.5/18 kW/Btu models: 3EA)
Pull the right and the left side.

Wiring Connection

1) Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively.
Screw
2. To check the drainage.
■ Pour a glass of water on the evaporator.
■ Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out
the drain exit.
Connecting cable
Installation Manual 13
Installation
Remote control cord
Remote control cord
Remote control cord

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi v art cool series

Table of Contents