Cleaning Table
USERS MANUAL
07/2008
138514_EN_BA_105

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the bio.x C500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Denios bio.x C500

  • Page 1 Cleaning Table USERS MANUAL 07/2008 138514_EN_BA_105...
  • Page 2: Table Of Contents

    Without approval from the manufacturer no changes, extensions or modifications may be made to the product. For changes made without approval from the manufacturer no liability is assumed and the guarantee expires. National regulations and safety regulations have to be adhered to. bio.x C500 135147 Page 2 of 12 07/2008...
  • Page 3: Safety Instructions

    The equipment must be set up on a suitable stable, level surface. Detergents which contain highly flammable substances must not be used. Use only detergents ap- proved by DENIOS for this unit. 3. Technical data Dimensions 1010 x 785 x 1140 mm...
  • Page 4: Product Description

    The bio.x parts cleaning unit is used to clean oil and grease from work pieces in an efficient, environmentally sustainable way using exclusively cleaning fluids authorised by DENIOS. Other detergents such as degreasers or alkali cleaning agents must not be used! Solvents, disinfectants, alkali or acidic fluids, carburettor and diesel fuels or turpentine must not be poured into the appliance.
  • Page 5: Initial Operation

    If such damage is found, do not connect the unit to the mains. Report damage immediately to the carrier who delivered the unit and to DENIOS AG at the service number indicated above. The original packaging should be kept.
  • Page 6: Function Indicators On The Display

    41º C again. The warm-up stage takes about an hour, depending on the ambient temperature. Once this temperature is reached and "41" is shown continuously on the display, the unit is ready for operation with optimum cleaning assured. bio.x C500 135147 Page 6 of 12 07/2008...
  • Page 7: Maintenance

    After you have taken out the used cleaning fluid, the tank has to be freed of any sediment residue. Please follow the same process when inserting the new fluid as for the initial operation. bio.x C500 135147 Page 7 of 12...
  • Page 8: Refill Items

    Hose between filter and tap 167923 Hose between pump and filter 167924 Hose bracket 141247 Hose for aerator 175289 Filter insert for fine filter (optional) 150043 Central support bracket and nylon filter bio.x C500 135147 Page 8 of 12 07/2008...
  • Page 9: Optional Accessories

    Two M8 screw threads are provided on the unit to retrofit a lid. Attach the lid using the socket cap screws supplied in the accessory kit. Warning: Do not tighten the screws too much as the user must be able to open the lid easily. bio.x C500 135147 Page 9 of 12 07/2008...
  • Page 10: Notes Regarding Disposal

    If overheating is not caused by the temperature sensor being in the wrong position, a service technician must be called in to find the cause and make necessary repairs. bio.x C500 135147 Page 10 of 12 07/2008...
  • Page 11: Connection Diagram

    12. Connection Diagram Thermal circuit breaker bio.x C500 135147 Page 11 of 12 07/2008...
  • Page 12: Ec Declaration Of Conformity

    13. EC Declaration of Conformity EC Declaration of Conformity For the purpose of the EC Machinery Directive 98/37/EC, Annex II A Herewith we, the DENIOS AG, Dehmer Straße 58-66, 32549 Bad Oeynhausen, declare that the design of our product: Cleaning Table bio.x...