Without approval from the manufacturer no changes, extensions or modifications may be made to the product. For changes made without approval from the manufacturer no liability is assumed and the guarantee expires. National regulations and safety regulations have to be adhered to. bio.x C500 135147 Page 2 of 12 07/2008...
The equipment must be set up on a suitable stable, level surface. Detergents which contain highly flammable substances must not be used. Use only detergents ap- proved by DENIOS for this unit. 3. Technical data Dimensions 1010 x 785 x 1140 mm...
The bio.x parts cleaning unit is used to clean oil and grease from work pieces in an efficient, environmentally sustainable way using exclusively cleaning fluids authorised by DENIOS. Other detergents such as degreasers or alkali cleaning agents must not be used! Solvents, disinfectants, alkali or acidic fluids, carburettor and diesel fuels or turpentine must not be poured into the appliance.
If such damage is found, do not connect the unit to the mains. Report damage immediately to the carrier who delivered the unit and to DENIOS AG at the service number indicated above. The original packaging should be kept.
41º C again. The warm-up stage takes about an hour, depending on the ambient temperature. Once this temperature is reached and "41" is shown continuously on the display, the unit is ready for operation with optimum cleaning assured. bio.x C500 135147 Page 6 of 12 07/2008...
After you have taken out the used cleaning fluid, the tank has to be freed of any sediment residue. Please follow the same process when inserting the new fluid as for the initial operation. bio.x C500 135147 Page 7 of 12...
Hose between filter and tap 167923 Hose between pump and filter 167924 Hose bracket 141247 Hose for aerator 175289 Filter insert for fine filter (optional) 150043 Central support bracket and nylon filter bio.x C500 135147 Page 8 of 12 07/2008...
Two M8 screw threads are provided on the unit to retrofit a lid. Attach the lid using the socket cap screws supplied in the accessory kit. Warning: Do not tighten the screws too much as the user must be able to open the lid easily. bio.x C500 135147 Page 9 of 12 07/2008...
If overheating is not caused by the temperature sensor being in the wrong position, a service technician must be called in to find the cause and make necessary repairs. bio.x C500 135147 Page 10 of 12 07/2008...
13. EC Declaration of Conformity EC Declaration of Conformity For the purpose of the EC Machinery Directive 98/37/EC, Annex II A Herewith we, the DENIOS AG, Dehmer Straße 58-66, 32549 Bad Oeynhausen, declare that the design of our product: Cleaning Table bio.x...