SECTION 502-9011-200
CHART 6
REPLACING THE MOUNTING CORD
STEP
PROCEDURE
1
Remove the base assembly and platform.
2
Disconnect the mounting cord leads from the network.
3
Loosen the screw to free the staycord hook, and remove the mounting cord. (See Fig. 5 [a] or
5[b]~
.
4
Replace the mounting cord. See Table C for connections.
CHART 7
REPLACING THE HANDSET CORD
STEP
PROCEDURE
1
Remove the earpiece cap from the earpiece
housing,
and discoanect the handset cord leads from
the receiver unit.
2
Unscrew the hook fitting (Fig. 8, Item 116) and pull the handset cord from the earpiece
housing.
3
Remove the cord restraint and pull the cord from the hook fitting.
4
Remove the handset cord from the telephone set base in a similar manner to the mounting cord.
(See Chart6, Fig.5[a) or S[b]).
5
Replace the handset
cord.
See Schematic Diagram, Fig. 6 or 7, for connections.
CHART 8
REPLACING THE SPIDER AND LEAD ASSEMBLY
OR BRACKET AND LEAD ASSEMBLY
STEP
PROCEDURE
1066
Unscrew the transmitter cap and remove the spider and bracket from the transmitter unit.
2
Remove the base assembly and platform.
3
Disconnect the leads from the network.
4
Release the leads from the screws and washers which clamp the leads to the inside of the
telephone set housing.
5
Pull the leads out through the transmitter housing assembly.
6
Replace the spider and bracket. See Schematic Diagram, Fig. 6 or 7, for connections.