Section 3: Maintenance; Annual Maintenance; Inspecting Vents; Cleaning Intake Filter - Generac Power Systems PWRcell 9 Owner's Manual

Hide thumbs Also See for PWRcell 9:
Table of Contents

Advertisement

Section 3: Maintenance

Annual Maintenance

DANGER
Electrocution. PWRcell Battery front cover should
be removed by a qualified technician only.
Removing the front cover could result in death,
serious injury,equipment or property damage.
On an annual basis:
Clean the exterior of the enclosure with a soft cloth.
Ensure surrounding area is free of leaves, pet hair
or other debris that could obstruct airflow in or out
of the unit.
Inspect the unit. Look for conditions that could
hinder performance or safety, such as (but not
limited to):
– Blocked vents
– Dirty intake filter
– Loose/missing hardware
– Loose or broken electrical connections.
NOTE: The 12V Blackstart battery should be inspected
annually by a qualified installer or technician. See
vice
for more information.

Inspecting Vents

See
Figure
3-1. Verify intake vent (A) and exhaust vent
(B) are clear at all times.
B
A
Figure 3-1. Intake Vent and Exhaust Vent
Owner's Manual for Generac PWRcell Battery
(000604)
Ser-
ON
OFF
0009890

Cleaning Intake Filter

1. See
Figure
3-2.
Grasp pull tab (C) and push frame
back to compress retention springs.
2. Pull tab down and out.
3. Slide filter out.
4. Clean filter with a vacuum cleaner, compressed air,
or water.
NOTE: Allow filter to dry before reinstalling.
5. Reinstall filter.
If air filter is damaged or becomes difficult to clean, con-
tact the nearest Independent Authorized Service Dealer
(IASD) or Generac Customer Service at 1-888-GEN-
ERAC (1-888-436-3722) or visit
replacement filter.
C
Figure 3-2. Cleaning Intake Filter
Maintenance
www.generac.com
for a
009897
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pwrcell 12Pwrcell 15Pwrcell 17

Table of Contents