Advertisement

Quick Links

IPS Wireless™ Repeater
Wireless Data Repeating Unit
PCN = xxxxxxxxxxx 8-14 (E)
Original Instructions
These instructions must be read prior to installing,
operating, using and maintaining this equipment.
USER INSTRUCTIONS
Installation
Operation
Maintenance
701-8001-01^

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPS Wireless and is the answer not in the manual?

Questions and answers

Summary of Contents for Flowserve IPS Wireless

  • Page 1 USER INSTRUCTIONS IPS Wireless™ Repeater Installation Operation Maintenance Wireless Data Repeating Unit PCN = xxxxxxxxxxx 8-14 (E) Original Instructions These instructions must be read prior to installing, operating, using and maintaining this equipment. 701-8001-01^...
  • Page 2: Table Of Contents

    7 PARTS LIST AND DRAWINGS ......9 7.1 S ..........9 PARE ARTS 7.2 D ............11 RAWINGS 8 TROUBLESHOOTING ........12 8.1 L ......12 OSS OF OMMUNICATIONS 8.2 I ......13 NACCURATE OR ISSING 9 CERTIFICATION ..........15 flowserve.com Page 2 of 19...
  • Page 3: Introduction And Safety

    Damage or failure caused safety requirements and applicable safety and health by misuse is not covered by the Flowserve warranty. laws/regulations. In addition, any modification of Flowserve products or...
  • Page 4: Safety

    If required the temperature or duty) it is requested that the user seeks operator may commission the manufacturer/supplier the written agreement of Flowserve before start up. to provide applicable training. 1.6 Safety Always coordinate repair activity with operations and 1.6.1 Summary of safety markings...
  • Page 5: Transport And Storage

    Prior to transport or storage, each unit in transportation. Any shortage and/or damage must should have the power source disconnected, the be reported immediately to Flowserve and must be battery disconnected and removed from the received in writing within ten days of receipt of the enclosure (the battery will need to be packaged equipment.
  • Page 6: Recycling And End Of Product Life

    When removing a unit from storage, follow the ready to use for receiving and re-transmitting wireless installation procedure in this document. data signals from any IPS Wireless device. 3.1 Options and Model Numbers 2.4 Recycling and end of product life...
  • Page 7: Battery Replacement

    CLASS I, DIVISION 2 RATING. DO NOT 5. Connect battery cables to terminals of new DISCONNECT BATTERY OR EQUIPMENT battery. UNLESS AREA IS KNOWN TO BE NON- 6. Reconnect battery and DC power HAZARDOUS. supply/solar panel fuses. flowserve.com Page 7 of 19...
  • Page 8: Tools Required

    Next, install the solar panel (if applicable) facing the equator with a tilt of location latitude +15 degrees (eg. 45 degrees for Houston, TX) from horizontal. flowserve.com Page 8 of 19...
  • Page 9: Connecting Wiring And Power-Up

    No spare parts are needed during start-up; recommended quantities of 2-year operational spares are listed below. Figure 4: Sample wiring diagram for repeater Next, install the battery inside the enclosure and connect the Battery+ and Battery- wires to the flowserve.com Page 9 of 19...
  • Page 10 12V, 10W Pole mounting G2-0010 bracket for solar panel Replacement Fuse, 2.5A, 250V, Slo-Blo H0-0129 5x20mm. Littlefuse PN: 21802.5 Replacement Fuse, 1/2A, 250V, Fast- acting. H0-0122 5x20mm. Littlefuse PN: 217.500XP Table 1: Spare Parts for repeater flowserve.com Page 10 of 19...
  • Page 11: Drawings

    REPEATER ENGLISH 701-8001-01^ 08-14 Drawings Figure 6: Sample wiring diagram for repeater flowserve.com Page 11 of 19...
  • Page 12: Troubleshooting

     Unit not powered up supply will need to be replaced.  Unit out of range of receiver Contact the Flowserve factory for  Receiver not configured correctly assistance. b. Solar Panel: confirm the power See solutions below to each of the possible causes: coming out of the power regulator is 12VDC or higher.
  • Page 13: Inaccurate Or Missing Data

    Check receiver configuration to ensure it is set up to 3. Use a voltmeter to read the battery voltage receive data from this particular IPS Wireless system across the battery terminals. If the voltage is (refer to receiver instruction and operations manual).
  • Page 14 8.2.4 Receiver Not Configured Correctly Check receiver configuration to ensure it is set up to receive data from this particular IPS Wireless system (refer to receiver instruction and operations manual). If none of the above solutions are successful in getting data reception, contact the factory for additional support.
  • Page 15: Certification

    ATEX marking etc. If required, copies of other certificates sent separately to the Purchaser should be obtained from Purchaser for retention with these User Instructions. The following certifications are applicable for the repeater unit. flowserve.com Page 15 of 19...
  • Page 16 REPEATER ENGLISH 701-8001-01^ 08-14 10 DECLARATION OF CONFORMITY (TYPICAL) Flowserve Corporation 10920 West Sam Houston Parkway North Suite 950 Houston, Texas 77064 Declare in sole responsibility that the equipment: ELD-102-X Single Point Transmitters SELD-103-X Smart Point Transmitters ELD-FA-403-Receiver, AO/DO and Serial Modbus...
  • Page 17 Elec app for use in presence of combustible dust Part11 Protection by intrinsic safety iD Certificate Number: Sira 10ATEX2013 Notified Body: Sira Certification Services, 0518 Report Number: R20441A Markings: Notified Body: CSA International Report Number: 1005105 Markings: flowserve.com Page 17 of 19...
  • Page 18 The technical documentation required to demonstrate that the product meets the requirements of the Directives has been compiled by the signatory below and is available for inspection by the relevant enforcement authorities. Signed: _____________________________________________ Date: _______________________ Authorized Person, Rick Lawson General Manager flowserve.com Page 18 of 19...
  • Page 19 USER INSTRUCTIONS Your Flowserve factory contacts: FLOWSERVE REGIONAL Flowserve Corporation SALES OFFICES: 10920 W Sam Houston Parkway N, Suite 950 Houston, TX 77064 USA USA and Canada Phone: +1 832 375 0807 Flowserve Corporation Pump 5215 North O’Connor Blvd., Suite 2300...

Table of Contents