The Reload Key command copies the key in non-volatile memory (NKN)
to the volatile location (NKV). This allows a sophisticated system to change
the keys during operation and quickly revert back to the default key.
The Non-volatile Reset command (FF 07 FE 47 20 FE 2A FE 3B) sets
all non-volatile registers to their default values. When the configuration is
reset, the following message, shown in quotes, is sent out the UART at the
current baud rate, then the module is reset, similar to a power cycle:
"\r\nConfiguration Reset\r\n".
This reset can also be done by toggling the PB line as described in the
Restore Factory Defaults
section.
SECSTAT - Security Status
Volatile Address = 0xC9
This volatile read-only register provides status of the security features.
HumPRC
Series Security Status
TM
Read Command
Header
Size
Escape
Escape
0xFF
0x03
0xFE
0xFE
Figure 74: HumPRC
Series Transceiver Security Status Command and Response
TM
The command returns a single byte. Figure 75 shows the meanings of the
bits in the returned value byte.
HumPRC
Series Security Status Value
TM
Bit
Status
0
Reserved
0 = No volatile key is set
1
1 = A volatile key is set
0 = No non-volatile key is set
2
1 = A non-volatile key is set
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
Figure 75: HumPRC
Series Security Status Values
TM
Read Response
Address
ACK
Address
Value
0x49
0x06
0xC9
V
72
JOINST - Join Status
Volatile Address = 0xCA
This volatile read-only register shows the current or previous state of Join
activity since the module was last reset.
HumPRC
Series Join Status
TM
Read Command
Header
Size
Escape
Escape
0xFF
0x03
0xFE
0xFE
Figure 76: HumPRC
TM
Series Transceiver Join Status Command and Response
The command returns a single byte. Figure shows the meanings of the
returned value byte.
HumPRC
TM
Series Join Status Value
Bit
Status
Last Join Result (decimal):
Last Operation Successful
0x00: Module unpaired since restart
0x01: New key generated
0x02: Successfully sent address to another unit
0x03: Successfully sent address and key to another unit
0x04: Successfully obtained key from administrator
0x05: Successfully obtained address from administrator
0x06: Successfully obtained key and address from administrator
0x07: New address generated without key
0x08: New key generated without address
Last Operation Failed
0 - 5
0x0A: Fail: operation canceled
0x0B: Fail: timeout
0x0C: Fail: Invalid Generate Key and Address request
0x0D: Fail: Assignment message didn't contain key
0x0E: Fail: Administrator has no key to send when SECOPT:PSHARE=1
0x0F: Fail: Administrator has no address to send
0x10: Fail: Inconsistent Network Address Registers USRC, UMASK, LASTNETAD
0x11: Fail: LASTNETAD overflow
0x12: Fail: GET_KEY key and address change disabled.
Current Operation
0x20: Detecting PB sequence
0x21: Waiting for joining unit
0x22: Another joining unit detected. Joining is in progress.
+0x64: JOINACT – MODE_IND is active with pairing status, serial write
6
operations are inhibited
Figure 77: HumPRC
Series Transceiver Join Status Value
TM
Read Response
Address
ACK
Address
Value
0x4A
0x06
0xCA
73