5
-
Removing the Case(Fig.5)
1. Remove the eight screws A and then remove the Case.
-
Removing the Control Unit(G2F) (Fig.5)
1. Apply shorting solder to the PU flexible cable before disconnecting it from the connector.
2. Disconnect the two connectors.
3. Remove the two screws B.
4. Remove the Control Unit(G2F).
-
Removing the Service Mechanism Unit(G2B) (Fig.5)
1. Remove the two springs A and two springs B.
2. Remove the two screws C and then remove the Bracket.
3. Remove the four Dampers and then remove the Service Mechanism Unit(G2B).
Screw A
Screw A
Service Mechanism Assy(G2B)
Spring A
Damper
Sheet
5
6
Screw A
Screw A
Damper
Sheet
Control Unit(G2F)
Screw B
DEH-MG2047ZF/XU/UC
6
7
Screw A
Case
Screw A
Screw A
Screw A
Spring B
Screw C
Screw C
Spring A
Sheet
Screw B
7
8
Shorting solder
Spring B
Bracket
Sheet
Damper
Damper
Fig.5
8
A
B
C
D
E
F
65