  • Page 1 AXIS A9188 Network I/O Relay Module Installation Guide - Full Reference...
  • Page 2 Every care has been taken in the preparation of this cable (STP) and found to comply with the limits for a document. Please inform your local Axis office of any Class B digital device, pursuant to part 15 of the FCC inaccuracies or omissions.
  • Page 3 If its connecting cables are routed outdoors, the product Contact information shall be grounded either through a shielded network cable Axis Communications AB (STP) or other appropriate method. Emdalavägen 14 223 69 Lund The power supply used with this product shall fulfill the...
  • Page 5: Hazard Levels

    AXIS A9188 Network I/O Relay Module Safety information Hazard levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 6 • The Axis product shall be used in compliance with local laws and regulations. • Axis recommends using a shielded network cable (STP) CAT5 or higher. • To use the Axis product outdoors, or in similar environments, it shall be installed in an approved outdoor housing.
  • Page 7 WARNING • Risk of explosion if the battery is incorrectly replaced. • Replace only with an identical battery or a battery which is recommended by Axis. • Dispose of used batteries according to local regulations or the battery manufacturer's instructions.
  • Page 9 AXIS A9188 Network I/O Relay Module Installation Guide - Full Reference This full reference installation guide provides instructions for how to install AXIS A9188 Network I/O Relay Module on your network. • For a quick reference guide, see the printed AXIS A9188 Installation Guide – Quick Reference that is included in the package contents.
  • Page 10 AXIS A9188 Network I/O Relay Module • When the Axis product has reached the end of its useful life, dispose of it according to local laws and regulations. The product should not be disposed of together with household or commercial waste. See Disposal and recycling on page 3 .
  • Page 11: Installation Steps

    The Axis product shall not impair the intended operation of the panic hardware used in conjunction with it. • Wall and Ceiling Mount If using a junction box to mount the Axis product, the junction box shall be UL Listed. • Assign an IP Address The functionality of AXIS Camera Management has not been evaluated by UL.
  • Page 12: Hardware Overview

    AXIS A9188 Network I/O Relay Module AVHS Authentication key AXIS Camera Station licence Hardware overview For specifications of the hardware components, see . Supervised I/O and power connector (DC OUT) port 1–4 Supervised I/O and power connector (DC OUT) port 5–8...
  • Page 13 AXIS A9188 Network I/O Relay Module Tampering alarm input 10 12/24 V power connector (DC OUT) LED indicators, buttons I/O LED indicators (8x) I/O overcurrent LED indicator Control button Relay LED indicators (8x) Status LED indicator Network LED indicator I/O overcurrent LED indicator...
  • Page 14: Install The Hardware

    The Axis product, whether it is installed as a single elevator controller or in a system of controllers, shall not limit or weaken the intended use of the devices connected to it. The Axis product should be installed with a DIN rail on a wall (preferred) or a ceiling, with or without a junction box.
  • Page 15 4. Attach the product to the DIN rail 5. Connect the cables. See page 15. Connect the Cables CAUTION Disconnect power before connecting any wires to the Axis product. Never make connections while power is applied to the product. NO TICE TICE TICE •...
  • Page 16: Access The Product

    2. Enter the IP address or host name of the Axis product in the browser’s address field. If you do not know the IP address, use AXIS IP Utility to locate the product on the network. For information about how to discover and assign an IP address, see Assign an IP Address.
  • Page 17 AXIS A9188 Network I/O Relay Module If your network does not have a DHCP server the Axis product will use 192.168.0.90 as the default IP address. Recommended Methods in Windows® AXIS IP Utility and AXIS Camera Management are recommended methods for finding Axis products on the network and assigning them IP addresses in Windows®.
  • Page 18 7. For information about how to set the password, see page 20. Assign IP Addresses in Multiple Devices AXIS Camera Management speeds up the process of assigning IP addresses to multiple devices by suggesting IP addresses from a specified range.
  • Page 19 AXIS A9188 Network I/O Relay Module • AXIS Dynamic DNS Service (all operating systems). A free service from Axis that allows you to quickly and simply install your Axis network product. Requires an Internet connection without an HTTP proxy. For more information, see www.axiscam.net •...
  • Page 20: How To Set The Root Password

    AXIS A9188 Network I/O Relay Module How to set the root password To access the Axis product, you must set the password for the default administrator user root. This is done in the Configure Root Password dialog, which opens when the product is accessed for the first time.
  • Page 21: Specifications

    The total maximum output load of the Axis product depends on the power source. The voltage on the Axis product’s power outputs is 12 V DC or 24 V DC. The maximum load is the combined power from 12 V and 24 V. For example if you take 1A from 12V output no power is available from 24 V.
  • Page 22 AXIS A9188 Network I/O Relay Module The following table shows the available power after connection of the 0.3 A device in the example. Power source Available power Power over Ethernet802.3at Type 2 Class 4 12 – 3.6 = 8.4 W 8–28 V DC...
  • Page 23 AXIS A9188 Network I/O Relay Module Function Specifications Power and Ethernet Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3, 44–57 V DC Supervised I/O and Power Connector 7-pin configurable I/O terminal block for: • Auxiliary power (DC output) • Digital Input •...
  • Page 24 AXIS A9188 Network I/O Relay Module Important The recommended maximum cable length is 30 m (98.4 ft). Important The output circuits in this section are Class 2 power limited. Important The total power from all DC outputs are 12 W (PoE Type 2 Class 4) or 3.6 W (PoE Type 2 Class 3).
  • Page 25 AXIS A9188 Network I/O Relay Module Relay Jumper 3-pin relay jumper for enabling power to auxiliary equipment via the Relay connector. Inserting the jumper between 12 V or 24 V to COM causes the internal voltage to be connected to the COM terminal of the relay.
  • Page 26 AXIS A9188 Network I/O Relay Module Important The output circuits in this section are NEC Class 2 power limited. RS–485 connector (not used) 4-pin RS-485/RS-422 half duplex serial port: • +12 V DC • 0 V REF • A • B...
  • Page 27: Connection Diagrams

    • Resetting the product to factory default settings, page 20. • Connecting to an AXIS Video Hosting System service or AXIS Internet Dynamic DNS Service. For more information about these services, see the User Manual. • Connecting to AXIS Internet Dynamic DNS Service. See www.axis.com...
  • Page 28: Further Information

    The user manual is available at www.axis.com • To check if there is updated firmware available for your product, see www.axis.com/support • For useful online trainings and webinars, see www.axis.com/academy Warranty information For information about Axis’ product warranty and thereto related information, go to www.axis.com/warranty/...
  • Page 30 Installation Guide - Full Reference Ver. M2.2 AXIS A9188 Network I/O Relay Module Date: May 2017 © Axis Communications AB, 2016 Part No. 1742335...

Table of Contents