Page 1
View over 1170 other Axis products View list of all the other manufacturers we carry # Require Multiple Quantities? Email us for Bulk Pricing Scroll down to view the Axis 0820-001 | A9188 Product Data Sheet...
Page 4
For information about your nearest designated collection point, contact your local Contact information authority responsible for waste disposal. In accordance Axis Communications AB with local legislation, penalties may be applicable for Emdalavägen 14 incorrect disposal of this waste. 223 69 Lund...
AXIS A9188 Network I/O Relay Module Safety information Hazard levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Page 7
• Axis recommends using a shielded network cable (STP). • Axis recommends using a network cable of category CAT5e or higher. • To use the Axis product outdoors, or in similar environments, it shall be installed in an approved outdoor housing.
Page 10
AXIS A9188 Network I/O Relay Module Installation Guide - Full Reference This full reference installation guide provides instructions for how to install AXIS A9188 Network I/O Relay Module on your network. • For a quick reference guide, see the printed AXIS A9188 Installation Guide – Quick Reference that is included in the package contents.
Page 11
AXIS A9188 Network I/O Relay Module • When the Axis product has reached the end of its useful life, dispose of it according to local laws and regulations. The product should not be disposed of together with household or commercial waste. See Disposal and recycling on page 3 .
The Axis product shall not impair the intended operation of the panic hardware used in conjunction with it. • Wall and Ceiling Mount If using a junction box to mount the Axis product, the junction box shall be UL Listed. • Assign an IP Address The functionality of AXIS Camera Management has not been evaluated by UL.
AXIS A9188 Network I/O Relay Module Overview label Extra serial number label (2x) AVHS Authentication key AXIS Camera Station licence Hardware overview Supervised I/O and power connector (DC OUT) port 1–4 Supervised I/O and power connector (DC OUT) port 5–8...
Page 14
AXIS A9188 Network I/O Relay Module Tampering alarm input 10 12/24 V power connector (DC OUT) LED indicators, buttons I/O LED indicators (8x) I/O overcurrent LED indicator Control button Relay LED indicators (8x) Status LED indicator Network LED indicator I/O overcurrent LED indicator...
The Axis product, whether it is installed as a single elevator controller or in a system of controllers, shall not limit or weaken the intended use of the devices connected to it. The Axis product should be installed with a DIN rail on a wall (preferred) or a ceiling, with or without a junction box.
AXIS A9188 Network I/O Relay Module Note • The Axis product is considered standalone, and does not require constant connection to a computer for proper operation. The use of a connected computer is for local programming, downloading, and supplemental monitoring purposes only.
1. Open a browser and enter the IP address or host name of the Axis device. If you do not know the IP address, use AXIS IP Utility to find the device on the network. For information about how to discover and assign an IP address, see Assign an IP Address on page 17.
Assign an IP Address About default IP addresses Axis devices are designed to be used on an Ethernet network. To access the device’s webpage you need an IP address. Most networks have a DHCP server that automatically assigns IP addresses to connected devices.
Page 19
AXIS A9188 Network I/O Relay Module Change the IP address of a device 1. Start AXIS IP Utility. All available devices on the network show up in the list automatically. 2. Right-click the device in the list and select Assign new IP address to selected device.
Page 20
AXIS Camera Station To learn more, go to axis.com/vms • UPnP™ UPnP automatically detects Axis devices and adds them to Network or My Network Places. In Mac OS X® ® ® 10.4 or later • Bonjour (applicable to browsers with support for Bonjour) Navigate to the Bonjour bookmark in your browser, for example Safari, and click the link to access the webpage.
Utilities. How to set the root password To access the Axis product, you must set the password for the default administrator user root. This is done in the Configure Root Password dialog, which opens when the product is accessed for the first time.
Reset to factory default settings Maintenance Instructions To keep the network I/O module running smoothly, Axis recommends regular maintenance of the network I/O module and connected devices. Do maintenance at least once a year. The suggested maintenance procedure includes, but is not limited to, the following steps: •...
Page 23
The total maximum output load of the Axis product depends on the power source. The voltage on the Axis product’s power outputs is 12 V DC or 24 V DC. The maximum load is the combined power from 12 V and 24 V. For example if you take 1A from 12V output no power is available from 24 V.
Page 24
AXIS A9188 Network I/O Relay Module Area mm Diameter mm (in) 28–16 0.0810–1.31 0.321–1.29 (0.0126–0.0508) 22–14 0.326–2.08 0.644–1.63 (0.0253–0.0641) Connectors For information about the connectors’ positions, see Hardware overview on page 12. The following section describes the connectors’ technical specifications.
Page 25
AXIS A9188 Network I/O Relay Module 12 V DC For powering auxiliary See Power Consumption on page output equipment. Note: This pin can only be used as power out. 24 V DC For powering auxiliary See Power Consumption on page output equipment.
Page 26
AXIS A9188 Network I/O Relay Module Function Notes Specifications 0 V REF 0 V REF For connecting auxiliary equipment. 0 to max 30 V AC/DC 1 A When PoE powered, For connecting auxiliary equipment. relay output is only rated For connecting auxiliary equipment.
Page 27
AXIS A9188 Network I/O Relay Module Function Notes Specifications 0 V REF 0 V DC 12 V DC OUT For powering auxiliary See Power Consumption on page equipment. For powering auxiliary 24 V DC OUT See Power Consumption on page equipment.
• Resetting the product to factory default settings, page 21. • Connecting to an AXIS Video Hosting System service or AXIS Internet Dynamic DNS Service. For more information about these services, see the User Manual. • Connecting to AXIS Internet Dynamic DNS Service. See www.axis.com...
For the latest version of this document, see axis.com • The user manual is available at axis.com • To check if there is updated firmware available for your device, see axis.com/support • For useful online trainings and webinars, see axis.com/academy Warranty information For information about Axis’...