Connect to Fiber Under Test (FUT):
All fibers and connectors should be inspected and clean prior to connection, as described on page 1.
The OCC-4056 is typically connected to the FUT via a Monitor Port or splitter/tap to not disrupt service.
The OCC-4056 can also be directly connected to the common port or common fiber via a coupler
during turn up or maintenance:
1. Inspect the OCC-4056 port on top of the test set.
2. If connecting to the Common Cable, connect the Common Cable to an optical coupler with the
same connector type and inspect the fiber end face in the coupler.
3. If connecting to the Monitor Port or Common Port on the Mux, inspect the Mux Port.
4. Inspect the fiber end face of the Launch Cable.
5. Connect the Launch Cable to the OCC-4056 port.
6. Inspect the other fiber end face of the Launch Cable.
7. Connect the Launch Cable to the coupler or Mux port