Advertisement

Operating and Installation Instructions
Ventilation System
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the first
time.
en-US
M.-Nr. 11 467 740

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 2360

  • Page 1 Operating and Installation Instructions Ventilation System To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 11 467 740...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS .............. 3 Caring for the environment ................ 11 Guide to the appliance .................. 12 Description of functions .................. 14 Operation...................... 15 Turning on the blower.................... 15 Selecting the power level ..................15 Delayed shut-down ....................15 Turning off the blower....................
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 4  Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician.  A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS  Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS  Defective components should be replaced by Miele original parts only. Only with these parts can safety of the appliance be assured as intended by the manufacturer.  If the power cord is damaged, it must only be replaced by a qualified service technician.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS  WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS  Overheated oil and fat can ignite, causing fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat fryers unattended when cooking with oil or fat. Similarly, never leave an open flame unattended when grilling. ...
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS Proper installation  WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 10 Never use a steam cleaner to clean the ventilation hood. The steam can reach the electrical components and cause a short circuit. Accessories  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void.
  • Page 11: Caring For The Environment

    Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
  • Page 12: Guide To The Appliance

    Guide to the appliance...
  • Page 13 Overhead lighting c OdorFree charcoal filters (2 filters) Optional accessories for recirculation mode d Grease filters (DA 2360: 1 filter; DA 2390: 2 filters) e Controls f On/Off button for the blower g Buttons for setting the blower power...
  • Page 14: Description Of Functions

    Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the Recirculation mode hoods require a model: recirculation kit and OdorFree Charcoal Filters (available as optional Extraction mode accessories), see “Technical Data” for more information. The air is drawn in and cleaned by the grease filters and directed outside.
  • Page 15: Operation

    Operation Turning on the blower Turning off the blower  Press the On/Off control  to turn Switch the blower on as soon as you start cooking. This is to ensure that the blower off. vapors are captured right from the start. The ...
  • Page 16: Turning Power Management On/Off

    Operation Turning power management on/off Safety shut-off You can deactivate power If power management has been management. deactivated, the ventilation hood will Keep in mind that this may increase switch itself off automatically after energy consumption. 12 hours if it has been left on (blower and overhead lighting).
  • Page 17: Energy-Saving Tips

    Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: – Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels.
  • Page 18: Cleaning And Care

    Unsuitable cleaning agents can treating them with a stainless steel care damage the surfaces and control product (available from Miele). elements. Do not use any cleaning agents Important information for the containing soda, acid, chloride, or controls solvent.
  • Page 19: Grease Filters

    Cleaning and care Grease filters The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.) from the kitchen vapors, preventing soiling of the ventilation hood. The grease filters must be cleaned at regular intervals. Heavily soiled grease filters hinder air extraction and will lead to increased levels of soiling in the ventilation hood ...
  • Page 20: Odorfree Charcoal Filter

     Use a commonly available household OdorFree Charcoal Filter dishwashing detergent. With recirculation mode, two charcoal  In a Miele dishwasher use the filters must be installed in addition to “Normal” program. the grease filters. These are designed to absorb cooking odors.
  • Page 21: Disposing Of Charcoal Filters

    The light bulbs should be replaced with the following: Bulb type ......LED, GU10 Power ..........3W Light bulbs are available from Miele or specialist dealers.  Fit the charcoal filters into the frame.  Press the filters into the holders.
  • Page 22 Cleaning and care  Turn off the blower and the lighting.  The light bulbs can get very hot when in use. Allow the bulbs to cool down for a few minutes before changing them.  Disconnect the hood from the electrical supply before replacing the light bulbs (see “IMPORTANT SAFETY INSTRUCTIONS”).
  • Page 23: Technical Service

    Contracts offered by other providers for For further information, please refer to Miele products will not be recognized your warranty booklet. by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 24: Installation

    *INSTALLATION* Installation Before installation Installation materials  Before installation, it is important to read the information contained in this chapter and in the “IMPORTANT SAFETY INSTRUCTIONS” chapter. The ventilation hood is intended for installation in wall cabinets, ventilation housing units, vent flues or above kitchen islands.
  • Page 25 *INSTALLATION* Installation Keep the following in a safe place: Installation plan See the installation plan for details of the individual steps involved in the installation of this appliance. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
  • Page 26: Appliance Dimensions

    *INSTALLATION* Installation Appliance dimensions The drawing is not to scale...
  • Page 27 1" (25 mm) from the cut-out. c Alternatively, the ventilation hood can be secured to four fixing points on an interim shelf. d There are additional fixing points on the installation surface. Installation dimensions will differ if you are using the Miele DAA 6 adapter...
  • Page 28: Distance Between Cooktop And Ventilation Hood (S)

    Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
  • Page 29: Installation Recommendations

    *INSTALLATION* Installation Installation recommendations – Please note that the greater the distance from the cooktop, the less effective the hood is at drawing in the cooking vapors. – To achieve optimum vapor extraction, the ventilation system must be centered over the cooktop, not to the side or behind.
  • Page 30: Uneven Installation Surfaces

    *INSTALLATION* Installation Uneven installation surfaces If the installation surface is uneven making flush installation difficult, the frame can be realigned.  Fit the ventilation system as described on the installation plan.  Fit one of the screws supplied into  Disconnect the ventilation system each bulb holder.
  • Page 31: Air Venting

    *INSTALLATION* Installation – The exhaust ducting must not be Air venting kinked or compressed. WARNING: Danger of toxic fumes. – Ensure that all connections are Gas cooking appliances release strong and airtight. carbon monoxide that can be harmful or fatal if inhaled. Remember that any restriction of the To reduce the risk of fire and to air flow rate will reduce extraction...
  • Page 32: Condensate Trap

    *INSTALLATION* Installation Condensate trap Reducing Collar (optional accessory) If you would like to reduce the In addition to insulating the exhaust environmental impact of your ventilation duct, we recommend installing a system by limiting the CFM output the condensate trap to collect and Reducing Collar can be installed.
  • Page 33: Electrical Connection

    CSA C22.1-12, appliance to your power supply, Canadian Electrical Code, Part I. please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 34: Technical Data

    Technical data Blower motor 350 W Overhead lighting DA 2360 2 x 3 W DA 2390 4 x 3 W Total connected load DA 2360 356 W DA 2390 362 W Supply voltage, frequency 120 V AC, 60 Hz Fuse 15 A Power cord length 2.5 ft (0.75 m) Weight DA 2360 24.2 lbs (11 kg) DA 2390 28.6 lbs (13 kg)