Troubleshooting Tips - GE GeoSpring GT50C10BAM Owner's Manual And Installation Instructions

Table of Contents

Advertisement

Troubleshooting
Before you call for service....
Save time and money! Review the chart below first and you may not need to call for service.
CAUTION
For your safety, DO NOT attempt repair of electrical wiring, controls, heating elements or
other safety devices. Refer repairs to qualified service personnel.
Problem
OPERATION AND PERFORMANCE
Not enough or no hot
water
Water is too hot
OTHER
Water dripping down the
outside of the heater
Combined non-return/
safety valve producing
popping sound or
draining
Water Not Filling Heater
Possible Causes
Water temperature may
be set too low
Hot water usage pattern
exceeds the capability of
the water heater in current
mode
Cold water inlet
temperature may be
colder during the winter
months
Leaking or open hot
water faucets
Long runs of exposed
pipe, or hot water piping
on outside wall
Water Connections to
unit reversed
Recirculating System
Interference (if installed)
Check installation
is south facing with
minimized shading
Water temperature is set
too high
Mixing valve has failed
Hot/Cold water connections
or other parts have loosened
Pressure buildup caused
by thermal expansion to a
closed system
The combined non-return/
safety valve will open at 72
PSI
Cold Water supply is off
Combined non-return/safety
valve
What To do
• See the Water Temperature Adjustment and Water Heater
• Wait for the water heater to recover.
This is normal. The colder inlet water takes longer to heat.
• Consider increasing the set temperature as described in the
Water Temperature Adjustment section.
• Make sure all faucets are closed.
• Insulate piping.
• Correct piping connections.
• Check flow rate is not set too high.
• Insulate piping
• Correct installation to face south and minimize shading
• See the Water Temperature Adjustment section.
• Contact your local installer, plumbing contractor, or
previously agreed upon service agency.
• Tighten the loose connections. This should only be done by a
qualified service person.
• This is an unacceptable condition and must be corrected. See
outlet. Contact your local installer, plumbing contractor, or previously
agreed upon service agency to correct this.
Reduce system water pressure
Check all valves to ensure system can be filled with water
The combined non-return/safety valve has a check valve integrated.
If installed backwards, flow can be prevented from filling the water
heater.