Installation Instructions
ON-ROOF INSTALLATION
4. Attach Flexible Bracket to the Collector Panel
of each of the Flexible Brackets with the
head toward the panel. Attach a washer and
a nut to the end of each bolt. Do not tighten.
side of the panel. Do this on each side.
groove.
5. Final Installation Steps
NOTICE: Risk of Unit Damage
Do NOT insulate combined non-return/safety
valve or ventilation valve. The water heater
warranty does not cover damage or failure
resulting from operation with insulated
valves.
valve installation section)
NOTICE:
Do not use more than 30 ft-lbs torque!
Cold Water
Inlet
90°
Flexible
Mounting
Bracket
Metric T-Head Bolt
Flat Washer
Metric Nut
NOTICE:
Do not use more than 30 ft-lbs torque!
GeoSpring Solar system but never before the
system is filled!
Hot Water
Outlet
Flat Seal
49-6000121 Rev. 0