  • Page 1 EO Basic Installation & User Guide V1.0 © 2019 Juuce Ltd t/a EO Charging. All rights reserved.
  • Page 2: Table Of Contents

    Power Up..........................11 Normal Operation ......................... 11 Fault Conditions ........................11 5.3.1 What should I do if a fault occurs? ................11 Further Technical Support ......................12 EO Basic Installation & User Guide V1.0 Page 2 of 12 08 October 2019...
  • Page 3: Introduction

    1 Introduction This document details the installation instructions for the EO Basic. It includes: • How to mount and wire up the EO Basic • How to set the current rating using the rotary switch (if option has been selected) •...
  • Page 4: Installation Instructions The Eo Mini

    2) Unscrew the locking plate from the base plate using the tool provided 3) Offer up the base plate. Level the base plate against the wall (or EO Post). Fix the base plate to the wall/post using the 4mm holes.
  • Page 5 5) Using a hole cutter, cut a hole into the rear plate connector for the gland. 6) Fit the correct sized gland for your power cable. EO Basic Installation & User Guide V1.0 Page 5 of 12 08 October 2019...
  • Page 6 Prepare the ends with ferrules. 8) Connect the power cables to the pins as shown – Single Phase or Three Phase 9) Replace the cover EO Basic Installation & User Guide V1.0 Page 6 of 12 08 October 2019...
  • Page 7: Important Installation Information

    The installer must select the RCD and earthing configuration in accordance with local regulation & best practice. Where the EO Basic includes DC leakage protection (DCL) a Type A RCD can be fitted at the supply. Otherwise a Type B RCD or equivalent should be used. EO recommend a 20A supply rated supply circuit for a 16A charging station and 40A supply for on 32A charging station.
  • Page 8: Setting The Maximum Current

    3 Setting the Maximum Current 3.1 Standard EO Basic On the standard EO Basic, it is not possible to change the maximum current value. This is only set in the factory 3.2 Optional Reverse Position Switch (RVPS) At the point of ordering, a cost extra can be specified which allows the installer to change the maximum current of the EO Basic.
  • Page 9 The maximum current should be set to the following values Switch Position Mains Test Enabled Maximum Current Rating 0 (OFF) TN-C-S or PME or TT systems IT systems EO Basic Installation & User Guide V1.0 Page 9 of 12 08 October 2019...
  • Page 10: Normal Operation

    4.1 Starting a charging session 1) Unlock the vehicle 2) Plug the cable into the vehicle 3) Plug the other end of the cable into the EO Basic 4) The charging session shall start 4.2 Stopping a charging session 1) Stop the charging session from the vehicle e.g. by unlocking the vehicle...
  • Page 11: Lights

    LED solid YELLOW The unit has been put on pause by an external system e.g. EO Hub, EO ALM or an external system 5.3 Fault Conditions The charging stations can detect certain fault conditions and when a fault condition is detected then the LED flashes RED a certain number of times to indicate the nature of the fault.
  • Page 12: Further Technical Support

    6 Further Technical Support All EO Charging technical documentation is published in the EO Resource Centre, this is found at: https://www.eocharging.com/service-support/ The EO Support team can be reached at: • Email: support@eocharging.com • Phone: +44 (0) 333 77 20383 EO Basic Installation & User Guide V1.0...