TAGLab C4 User Manual page 15

Table of Contents

Advertisement

Battery not
accepting charge
High charging time
Battery voltage
too low.
__________________________________________________________________________________________________________________
TAGLab
No mains voltage, charger not connected.
Faulty connections to battery terminals
In the event of low temperatures (under 0°C), the
charge is only performed with a very low current.
This will extend the charging time. As the battery
warms up, the charging current is adjusted
accordingly.
Battery capacity too high for the charger used.
Battery not charged for long enough.
Make sure that the charger is
plugged into a 230V / 50Hz mains
socket and that the "Power" LED
indicator lamp (12) goes on. The
battery may also be defective
Unplug the charger and check the
battery connection; ensure that
there is a good connection at the
battery terminal/post and/or vehicle
chassis.
Charge the battery in normal
conditions.
Risk of explosion.
Never charge frozen batteries.
Use a suitable charger.
Make sure that the battery was
charged for a sufficient amount of
time.