Maintenance; Diagnostic; Charging Phases - TAGLab C4 User Manual

Table of Contents

Advertisement

Do not connect to the mains input.
After 2 seconds, the "Power" LED will light up.
"Full" LED will light up if voltage is between 13.3V and 15.5V which means alternator system is OK.
If voltage is lower than 13.3V or higher than 15.5V. "Error" LED will light up which means alternator is in bad
condition.

Maintenance

Maintaining the Charge
The charger automatically switches to charge holding when the battery is recharged. If the energy is
removed from the battery during the charge holding, the charging current increases accordingly. The
charger can remain connected to a battery without any harmful overcharge.
Incorrect Polarity
Disconnect the charger from the mains and correct the connection to the battery.

Diagnostic

The diagnostic function is provided to automatically check the status of the battery and recognize the
voltage.
Voltage
0 V to 1.5 V
1.5 V to 12 V
12 V to 13 V
14.6 V
>15 V

Charging Phases

The charger uses a 9-stage charging process designed to optimally charge and maintain batteries. (The
below illustration show the charging phases when charging a 12V deeply discharged battery)
__________________________________________________________________________________________________________________
TAGLab
Function
"Error" LED (9) lit. Battery defective.
Charging starts.
Maintenance charging starts.
Battery fully charged. "Full" LED (10) lit.
"Error" LED (9) lit.
Battery Charger | C4