Invacare MK5 NX Service Manual page 37

Electronics
Hide thumbs Also See for MK5 NX:
Table of Contents

Advertisement

4
E04
Right Motor Fault
5
E05
Left Park Brake
Fault
6
E06
Right Park Brake
Fault
Part No 1110532
00
Right Motor Short Circuit
01
Right Motor Open Circuit
02
Right Motor Connection Fault
B-
03
Motor Terminal Connected
to B+
04
Right Motor Voltage Fault
05
Right Motor Bridge Fault
06
Too Many Hardware Cur-
rent Limit Events
07
Current Offset Out of Range
08
Hardware Current Limit Fault
00
Left Park Brake Drive-Time
Test Failed
01
Left Park Brake Output
Enabled When Wheelchair
Idle
02
Left Park Brake Output Did
not Enable When Entering
Drive Mode
03
Left Park Brake fault during
power-up testing
04
Left park brake feedback low
during drive (park brake
short)
00
Right Park Brake Drive-Time
Test Failed
01
Right Park Brake Output
Enabled When Wheelchair
Idle
02
Right Park Brake Output Did
not Enable When Entering
Drive Mode
03
Right Park Brake fault during
power-up testing
04
Right park brake feedback
low during drive (park brake
short)
37
SECTION 9—DIAGNOSTIC CODES
Check the right motor, connections and
motor cable.
Check the left park brake connections and
cable.
Check the right park brake connections
and cable.