K-750 Drain Cleaning Machine
Figure 8 – Release Belt Tension
Figure 9 – Remove Bolt Which Fastens Drum Assembly
to Machine Frame
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
12
Figure 10 – Lift Drum from Mounting Position
4. Lay machine back so that it rests on handles. Grasp
drum with both hands and lift it out of its mounting po-
sition on machine (Figure 10).
CAUTION
your knees and lift with your legs.
5. To install drum assembly, place it in its mount on
machine frame. Drum assembly should slide onto
shaft mounted on frame.
6. Carefully return machine to its upright position and re-
verse Steps 1 through 3 to prepare machine for
operation.

Pigtail Removal and Installation

FOR/OFF/REV SWITCH should be OFF and machine
is unplugged before removing or installing pigtail.
1. Remove all cable from the drum except the pigtail.
2. Remove the bolt anchoring the pigtail. It is located on
the back of the drum (Figure 11).