INDEX PAGE 3 Index ..............Getting started ............ 4 - 5 Connections ............Controls .............. 7 - 8 Status icons ............PurgeNet™ interface ..........Care and maintenance ......... Warning .............. Other languages ..........Customer support and worldwide care ....Warranty ............. Address and contact details ........
gETTINg STarTED PAGE 4 Your PurgEye 1500 Site IP68 Weld Purge Monitor is a ® ® portable battery or mains electricity operated instrument to read from 0.1% (1000 ppm) down to 0.0001% (1 ppm) oxygen. Your PurgEye 1500 Site IP68 Weld Purge Monitor delivery ®...
Page 5
gETTINg STarTED continued PAGE 5 4. Wait for the sensor to warm up, shown on the display. 5. Set your inert gas regulator for an outlet pressure of 0.5 bar and a flow rate of 7-10 litres/minute. When purging at higher flow rates, ensure that there is another exhaust outlet available so that all of the exhaust gas doesn’t come through the monitor.
(white). NOTE: The Quick Fit fittings and the filter can only be used with the special tubing supplied with the monitor. Do not attempt to use other tubing. Contact HFT if spare tubing is required and it ®...
cONTrOlS PAGE 7 Function The function button is used to operate the sample pump and activate the mute and power on/off functions. Holding the function button for more than 1 second will turn your PurgEye 1500 Site IP68 on or off. ®...
Page 8
cONTrOlS continued... PAGE 8 language and version information NOTE: Indicated by a speech symbol to the left of the display. NOTE: If the language is left blank (non selected, this is the default) then the device will scroll through all installed languages. NOTE: Connecting PurgNet™...
STaTUS IcONS PAGE 9 When necessary, the following four status icons will be displayed on the right hand side of the display. Display units This will be either ‘PPM’ or ‘%’ for oxygen concentration values. Press and hold ‘display’ button to change the display units. Battery status When the PurgEye 1500 Site IP68 is running on batteries a filled...
PUrgENET™ INTErfacE PAGE 10 Smart accessories: When supported, PurgeNet™ accessories are connected to the PurgeNet™ interface connection, they will be automatically detected by your PurgEye Site and extra menu options may appear, as ® required. Language Support current support: The PurgEye 1500 Site IP68 product range ®...
carE and MaINTENaNcE PAGE 11 Zirconium Oxide Sensor Care As a general guideline, the gases to be measured should be free from dust, organic vapours, condensation and products capable of condensing. Such components can block the gas conduits in the sensor and cause permanent damage.
MUST ALWAYS be used, or your PurgEye may read incorrectly ® and/ or be permanently damaged. Spare filters available from your HFT Distributor. ® Internal Pump The internal pump should not be force fed with any pressure as it may be damaged.
Other laNgUagES in PrOgrESS PAGE 13 Les autres langues sont actuellement dans le progrès. Pour le moment, s’il vous plaît contacter votre Distributeur local. Andere Sprachen sind momentan im Gange. Kontaktieren Sie vorläufig, bitte Ihren örtlichen Verteiler. Otros idiomas estan actualmente en progreso. Por ahora, por favor contacte su Distribuidor local.
For further information and support, please contact us at: Internet: www.huntingdonfusion.com Email: hft@huntingdonfusion.com Tel: +44 (0) 1554 836 836 Worldwide Offices, Partners and Distributors are listed on our website or contact us and we will direct you to the correct location...
Should you encounter a problem with your product, please notify us immediately upon receipt. Huntingdon Fusion Techniques HFT warrants this product to be ® free of defects in workmanship and material, with exceptions stated below.
Need help?
Do you have a question about the PurgEye Weld Purge Monitors Series and is the answer not in the manual?
Questions and answers