Setup tips:
 If, without the interface, your speedometer reads much too fast, then you will most likely need
to use application 3.
 If, without the interface, your speedometer reads about ½ what it should, then you will most
likely need to use application 6.
 If your speedometer reads close to actual speed, you will probably need application 1 or 2.
 If, without the interface, your speedometer reads much too slow, then you will most likely need
to use application 7.
Here is a general overview of the SGI-5 E's control functions.
Each of the different applications below will be described in detail starting on
page 4 in this manual.
Setup
Set output mode: Select the output mode depending on your application.
:
high speed in, high speed out. OUT3&4 = ½ of OUT1, OUT5 = ¼ of OUT1
:
high speed in, low speed out.
OUT3 =
:
low speed in, high speed out. OUT3&4 = x16 of OUT1, OUT5 = x8 of OUT1
:
low speed in, low speed out. OUT3&4 = ½ of OUT1, OUT5 = ¼ of OUT1
1. Begin with the key off.
2. Press and hold the SET switch while turning the key on. The display will show the current version
code.
3. Release the SET switch. The display will show "".
4. Press and release the SET switch. The current output mode will be shown, , , , or .
Press and release the INC switch to change the output mode. Press and release the SET switch
to save it.

Advanced Setup

Change input signal settings: These settings are set automatically when the output mode is
selected. If needed, they can be manually changed. The signal type can be changed between low
voltage and high voltage signal types. The input pullup can be turned on or off.
:
 or 
:
 or 
1. Begin with the key off.
2. Press and hold the SET switch while turning the key on. The display will show the current version
code.
3. Release the SET switch. The display will show ""
4. Press and release the INC switch until "" is shown.
5. Press and release the SET switch. Press and release the INC switch to select "", "", or
"".
6. Press and release the SET switch. Press and release the INC switch to change the setting, press
and release the SET switch to save it.
of OUT1, OUT4 =
1/16
of OUT1, OUT5 =
1/32
2
of OUT1
1/64