Intercom Server GE 150
Connection diagram
Expansion jack
Input
IP
Music / Alarm
GE 150
MUSIC
RS-232
IN1
DIP switches
IN2
Inputs for
floating
1234
contacts
OUT1
OUT2
OUT1 OUT2
Floating outputs
Cable run
GE 150
Cable bearer
4
/
RJ11/RJ45 socket
Slot number
1
2
3
4
5
Status LED
M3
–
+24V
A
A
B
B
C
C
D
D
M3
Grounding point
for wrist strap
grounding
+24V
–
Cable
bearer
A
B
C
D
Cable clamp NAK 100
140 cm
(55.1 in)
Analogue
Mounting, Dimensions
Measuring units in mm (in), not scale!
Power
ON
OFF
*
* Protection against contact acc. to IEC/EN 60950-1: For installation in the
operator access area, the housing cover has to be screwed onto the housing.
Warning
This is a Class A product. In a domestic environment this product may cause radio inter ference in
which case the user may be required to take adequate measures.
Latest software and documentation
To download the latest software and documentation, enter the PIN code to
the right at pin.commend.com
Attention
Observe the precautions for handling of electrostatic sensitive devices!
The device may only be installed by authorised engineers!
Disposal and recycling
Equipment with this symbol shall not be disposed of together with household or commercial
waste.
The directive 2012/19/EU on waste electrical and electronical equipment (WEEE) is applicable
in the European Union member states.
Manufacturer's reference
This device complies with the European directives listed below by fulfilling
corresponding standard:
• Electromagnetic compatibility (directive 2014/30/EU)
• The restriction of the use of certain hazardous substances in electrical and
electronic equipment (directive 2011/65/EU)
For technical specifications, see the respective manual.
Keep this description in safe custody.
Type: D-BZ-GE150, Version: 1.3/0318
306 (12.1)
290 (11.4)
GE 150
Attention
Achtung: Darf nur durch geschultes Personal geöffnet werden
Attentie: Mag alleen geopend worden door gekwalificeerd personeel!
OBSERVE PRECAUTIONS FOR HANDLING
Attention: May only be opened by qualified persons!
Attenzione: Darf nur durch geschultes Personal geöffnet werden
OF ELECTROSTATIC SENSITIVE DEVICES!
Attention: Seul ie personnel qualife est autorise a l ouvrir!
Atencion: Darf nur durch geschultes Personal geöffnet werden
Commend International GmbH, Saalachstraße 51, A-5020 Salzburg – www.commend.com
*
PIN-CODE
CC23AF 7E1C51
Valid until 30-12-2018
pin.commend.com
Need help?
Do you have a question about the GE 150 and is the answer not in the manual?
Questions and answers