Lamp replacement (Continued)
1
Unplug power cord.
2
Wait until lamp is sufficiently cooled.
Wait for at least 1 hour.
3
Remove the lamp cover.
Loosen the two screws, raise the outer lamp
cover with your fingers as shown to remove
the outer lamp cover. Use care to avoid any
damage to nails and/or tip of your finger(s). If
you have any difficulty in removal, you can use
a screwdriver or any other smaller tool for your
convenience.
4
Pull out the lamp.
Loosen the two lamp locking screws, pull up the
handle to remove the lamp.
5
Mount the new lamp.
Align the orientation, press down the new lamp
until the bottom is reached, and lock in place using
the two lamp locking screws.
6
Replace the lamp cover.
Align the cover,and press it in,then tighten the
screws loosend in step
no longer loose.
3
until the lamp cover is
36
Lamp cover
3
1
4
2
5
2
1
1