Download Print this page

UNI-T 165H User Manual

Professional thermal imager

Advertisement

165H
Professional Thermal Imager
User Manual
P/N:110401109192X

Advertisement

loading

Summary of Contents for UNI-T 165H

  • Page 1 165H Professional Thermal Imager User Manual P/N:110401109192X...
  • Page 2 UTi165H User Manual Preface Thank you for purchasing this brand new product. In order to use this product safely and correctly, please read this manual thoroughly, especially the safety notes. After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
  • Page 3: Table Of Contents

    165H User Manual 165H User Manual 1. Safety Instructions To ensure proper use of this product, please read the instructions carefully before using. Table of Contents The optimal measuring distance for this product is 1 meter. To ensure measurement accuracy, please use the product in an operating environment of 15°C~30°C, <85% RH (non-condensing).
  • Page 4: Structure

    165H User Manual 165H User Manual 3. Display 2. Structure Display size: 2.8” Display resolution: 320 (vertical) x 240 (horizontal) pixels Description Description Item Item Description Description Item Item Temperature unit option Maximum temperature point Tripod mounting hole Micro SD card slot...
  • Page 5: Menu Introduction

    165H User Manual 165H User Manual 5. Menu Introduction 6.Operating Instructions 6.1 Temperature Unit Selection 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to enter the temperature unit submenu.
  • Page 6 165H User Manual 165H User Manual 6.4 High/Low Temperature Alarm To track high temperature: 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to enter the cursor submenu.
  • Page 7 165H User Manual 165H User Manual 6.5.1 Language 6.5.3 Emissivity/Temperature Compensation To set emissivity/temperature compensation: To set language: 1. Press the up/down button to select the Emissivity option in the Settings menu. 1. Press the up/down button to select the Language option in the Settings menu.
  • Page 8 165H User Manual 165H User Manual 6.5.7 Alarm Temperatures 6.5.5 Display Brightness To set alarm temperatures: To set display brightness: 1. Press the up/down button to select the HI/LO Alert option in the settings menu. 1. Press the up/down button to select the Brightness option in the settings menu.
  • Page 9: Usb Communication

    SD card is replaced during use, restart the device after the replacement to take and save pictures. 7.USB Communication 1. Download and install the PC software (refer to UNI-T Documents Download Operation Guide). 2. Connect the USB cable to the PC.
  • Page 10: Specifications

    165H User Manual 165H User Manual 8. Specifications General parameters PC software UFPA Sensor Type-C USB interface Data transmission Temperature range 30°C~45°C Product size (L x W x H) 236mm x 75.5mm x 86mm 0.1°C Measurement resolution Display type ±0.5°C (at 25°C ambient temperature) 2.8”...

This manual is also suitable for: