pplication
Modern design flush mounting fan coil room thermostat, used for individual control of temperature in commercial, industrial and
residential buildings. It is tailored for two-pipe and four-pipe fan coil units with two-wire electric valves. The device combines digital
technology with a large LCD touch screen display, which enables the single room controller to be used intuitively. Integrated 7 day
time clock with 4 time programs.
S
ecurity Advice – Caution
The installation and assembly of electrical equipment should only be performed by authorized personnel.
The product should only be used for the intended application. Unauthorised modifications are prohibited! The product
must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human
health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before
installing. Do not connect to live/operating equipment.
CAUTION! Risk of electric shock due to live components within the enclosure, especially devices with mains
voltage supply (usually between 90..265 V).
Please comply with
Local laws, health & safety regulations, technical standards and regulations
Condition of the device at the time of installation, to ensure safe installation
This data sheet and installation manual
N
otes on Disposal
As a component of a large-scale fixed installation, Systemair products are intended to be used permanently as part
of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act
(WEEE) is not applicable. However, most of the products may contain valuable materials that should be recycled
and not disposed of as domestic waste. Please note the relevant regulations for local disposal.
Systemair GmbH Germany
info@systemair.de
oder
http://www.systemair.de/

Advertisement

Table of Contents
loading

Summary of Contents for SystemAir TControl Touch 3s

  • Page 1 Disposal As a component of a large-scale fixed installation, Systemair products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable.
  • Page 2: Technical Data

    ABS, scratch-resistant acrylic glass Protection IP20 according to EN 60529 Connection electrical terminal block max. 1,5 mm² Ambient condition -10..+50 °C, max. 85% rH non-condensing Weight 160 g Mounting flush mounted with standard EU box (Ø=55 mm) Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 3: M Ounting Advices

    TContol Touch 3s black – Auto mode wiring diagram for 2-pipe fan coil TContol Touch 3s black – Manual mode wiring diagram for 2-pipe fan coil TContol Touch 3s black – wiring diagram for 4-pipe fan coil Systemair GmbH Germany info@systemair.de oder...
  • Page 4 Display °C or °F Display of the units °C or °F can be selected using parameter No. 12. Fahrenheit temperature display range is 32..99 °F, °C temperature display range is 0..50 °C. Factory default is °C. Systemair GmbH Germany info@systemair.de oder...
  • Page 5 ” button, the parameter to be changed is flashing. Then select “ ” or“ , set the time like the following image to leave the timer mode: “ ” . The system saves the user settings to set the timer on / off automatically. Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 6 4 programmable periods can be set. → hour → minute →temperature 1 → hour→ minute→ temperature 2 → hour→ minute→ temperature 3 → hour → minute → temperature 4 Individual passwords setting Factory default :260 Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 7: C Ommunication Modbus

    4800 bps / 9600 bps / 19200 bps / 38400 bps (optional) Factory default: 9600 bps Parity: no parity / odd parity / straight parity (optional) Factory default: no parity Data: 8 bit Stop: 2 bit Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 8 001-999 Stopbit 1=1bit, 2=2bit Infrared receiver (remote) 0 – deactivated, 1 - activated All parameters are stored within an EEPROM (electrically erasable programmable ROM), ensuring no data loss if the Thermostat is powered off. Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 9 Read -only 2:cool&heat 2pipe, 0x0007 0x04 4:cool&heat 4pipe, 6:cooling+electr-heater 30009 version Read -only 1010(0x03F2)-9999(0x270F),for 0x0008 0x04 example:1110(0x0456) and communciation protocol version V1.3, software version V1.7 30010 External temp sensor Read-only 0x0009 0x04 0-00-500(0x01F4),e,g:245=24.5℃ Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 10 00-59 0x001B 0x03,00x06,0x10 40029 system time--seconds Read /Write 00-59 0x001C 0x03,00x06,0x10 40030 system week Read /Write 1=Sun ,2=Mon ,3=Tue ,4=Wed 5=Thu 0x001D 0x03,00x06,0x10 6=Fri 7=Sat 40031 IR receiver Read /Write 0=OFF, 1=ON 0x001E 0x03,00x06,0x11 Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 11: Dimensions (Mm)

    Issue date: 13.02.2018 Page 11 / 22 imensions (mm) Display unit: Base plate: Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 12 Die technischen Daten sowie die Bedienungsanleitung des Gerätes ntsorgungshinweis Als Einzelkomponente von ortsfest installierten Anlagen fallen Systemair Produkte nicht unter das Elektro- und Elektronikgesetz (ElektroG). Die meisten unserer Produkte enthalten wertvolle Rohstoffe und sollten deshalb nicht als Hausmüll entsorgt, sondern einem geordneten Recycling zugeführt werden. Die örtlich gültige Entsorgungsregelung ist zu beachten.
  • Page 13: Technische Daten

    Gehäuse ABS, kratzfestes Acrylglas Schutzart IP20 gemäß DIN EN 60529 Anschluss elektrisch Schraubklemme max. 1,5 mm² Umgebungsbedingung -10..+50 °C, max. 85% rH nicht kondensierend Gewicht 160 g Montage Unterputz in Standard UP-Dose (Ø=55 mm) Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 14 Befestigen Sie die Grundplatte mit der Frontabdeckung. Vermeiden Sie jeglichen Druck auf das Display, um es vor etwaigen Beschädigungen während der Installation zu schützen. nschlussplan TControl Touch Standard – 2-Rohr mit Change-Over TControl Touch Standard – 2-Rohr manueller Typ TControl Touch Standard – 4-Rohr Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 15 Auswahl der Betriebsart (über die MODE-Taste): Manueller Modus: 2-Rohr-System: Kühlen  Lüften  Heizen 4-Rohr-System: Kühlen  Lüften  Heizen  Auto Change-Over Modus (nur wenn Parameter 14 auf 1 ist) AUTO-Modus: Die Betriebsart wird automatisch gewählt. Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 16 Unter Parameter 8 kann das Zeitformat (24h oder 12h) gewählt werden. Zeiteinstellung Drücken Sie die “ ” Taste, um Zeiteinstellungen vorzunehmen. Der zu ändernde Parameter blinkt, drücken Sie die “▲”oder“▼”-Taste zur Einstellung: Reihenfolge: Jahr→Monat→Tag Datum→Tag Name→Stunde→Minute→Timer EIN Stunden Minuten→Timer AUS Stunden Minuten→Jahr… Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 17 ändernde Wert erscheint (Stunde, Minute, Periode). Wertänderungen erfolgen mit ▲” oder“▼”. Die folgenden 4 programmierbaren Perioden können eingestellt werden. → Stunde → Minute →Temperatur1 → Stunde → Minute → Temperatur 2 → Stunde→ Minute→ Temperatur 3 → Stunde → Minute → Temperatur 4 Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 18 4800 bps / 9600 bps / 19200 bps / 38400 bps (optional) Werkseinstellung: 9600 bps Parität: keine Parität / ungerade Parität / gerade Parität (optional) Werkseinstellung: Keine Parität Data: 8 bit Stop: 2 bit Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 19 Einstellung individuelles Passwort 001-999 Stoppbit 1=1bit, 2=2bit Infrarot Empfänger (Fernbedienung) 0 - deaktiviert, 1 - aktiviert Alle Parameter sind auf einem EEPROM gespeichert, so dass keine Daten verloren gehen, wenn das Thermostat ausgeschaltet ist. Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 20 Read -only 2:cool&heat 2pipe, 0x0007 0x04 4:cool&heat 4pipe, 6:cooling+electr-heater 30009 version Read -only 1010(0x03F2)-9999(0x270F),for 0x0008 0x04 example:1110(0x0456) and communciation protocol version V1.3, software version V1.7 30010 External temp sensor Read-only 0-00-500(0x01F4),e,g:245=24.5℃ 0x0009 0x04 Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 21 00-59 0x001B 0x03,00x06,0x10 40029 system time--seconds Read /Write 00-59 0x001C 0x03,00x06,0x10 40030 system week Read /Write 1=Sun ,2=Mon ,3=Tue ,4=Wed 5=Thu 0x001D 0x03,00x06,0x10 6=Fri 7=Sat 40031 IR receiver Read /Write 0=OFF, 1=ON 0x001E 0x03,00x06,0x11 Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...
  • Page 22 Page 22 / 22 Issue date: 13.02.2018 bmessungen (mm) Display-Einheit: Grund-Gehäuse: Systemair GmbH Germany info@systemair.de oder http://www.systemair.de/...