Download Print this page
Festo NEBC-M8G4-ES-S1G9-RS2 Series Instructions & Assembly
Festo NEBC-M8G4-ES-S1G9-RS2 Series Instructions & Assembly

Festo NEBC-M8G4-ES-S1G9-RS2 Series Instructions & Assembly

Connecting cable

Advertisement

Quick Links

NEBC­M8G4­ES­...­S1G9­RS2
Connecting cable
Instructions | Assembly
8115217
2019-07
[8115219]
Translation of the original instructions
1
Applicable documents
All available documents for the product è www.festo.com/pk.
2
Safety
2.1
Safety instructions
Do not connect or disconnect plug connector when powered.
Only assemble the product on components that are in a condition to be safely
operated.
2.2
Intended use
Connecting cable for valve control modules VAEM-VS8RS2 and VAEM-VS8EPRS2
for parameterisation and commissioning via the RS232 port.
3
Configuration
3.1
Product design
Fig. 1
3.2
Contact assignment
Electrical connection 1
Field device side
1  Plug con-
Pin
Allocation/
nector
Signal
1
GND
2
RXD
3
TXD
4
Not assigned
1) pin 1,4,6 bridged
2) pin 7,8 bridged
Tab. 1 Contact assignment
4
Mounting
4.1
Mounting of electrical connection 1
1. Align the plug 1 to match the socket.
2. Insert the plug 1 into the socket.
3. Tighten the screw-type lock of the plug 1. Tightening torque: 0.4 Nm ± 10 %
4.2
Mounting of electrical connection 2
1. Align socket 2 to match plug.
2. Connect socket 2 to the plug.
3. Tighten 4 screws. Tightening torque: 0.3 Nm ± 10 %
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
8115217
1 Plug M8x1, A-coded
2 Sub-D socket
3 Cable
4 Screw (2x)
Electrical connection 2
Controller side
Allocation/
Pin
2 Socket
Signal
5
2
3
DCD
1)
1
1)
DTR
4
DSR
1)
6
RTS
7
2)
2)
CTS
8
Not assigned
9
4.3
Wiring
Character­
Cable characteristic
istic
-E-
Suitable for energy chains
Tab. 2 Wiring
4.4
Mounting in energy chain
1. Lay the chain out lengthwise.
2. Place the cables in the chain, making sure they are not twisted.
3. Separate cables from each other using separators/drill holes.
4. Do not connect cables together.
Fig. 2
5. Maintain space X. X > 10 % of the cable diameter D.
If the chain is suspended vertically: increase the space X.
Fig. 3
6. Align chain in the operating position:
Make sure that the radius is greater than the bending radius  R of the
cables.
Cables can move freely in the bending radius KR of the energy chain.
Ä Cables are not forced through the chain.
7. Mount the energy chain è corresponding instructions.
8. Fasten cables:
At both ends of the chain in case of short energy chains
Only at the driver end in the case of long, sliding energy chains
Fig. 4
9. Do not bend cables all the way to the fastening point.
Ä Mounting space A between the fastening point and bending movement is
observed.
NOTICE!
Damage to cables if the chain breaks.
Replace cables after a chain break.
NOTICE!
Malfunction and material damage due to vertically suspended cables.
The cables stretch.
Regularly check the length of the cables.
Readjust the cables if required.
Wiring
In energy chain or flexible

Advertisement

loading

Summary of Contents for Festo NEBC-M8G4-ES-S1G9-RS2 Series

  • Page 1 Fig. 2 Applicable documents 5. Maintain space X. X > 10 % of the cable diameter D. If the chain is suspended vertically: increase the space X. All available documents for the product è www.festo.com/pk. Safety Safety instructions – Do not connect or disconnect plug connector when powered.
  • Page 2 Technical data NEBC­M8G4­ES­...­S1G9­RS2 Cable characteristic Suitable for energy chains Cable composition [mm²] 3x0.34 Shielding Shielded Cable diameter [mm] Mounting space [mm] ³ 92 Current rating at 40 °C Surge resistance [kV] Operating voltage range 0 … 24 Bending radius Fixed cable installation [mm] ³ 24 Flexible cable installation [mm] ³ 47...