Download Print this page

Audipack FS-QR120 E Mounting And Manual Instruction

Floor stand

Advertisement

Quick Links

Mounting and manual instruction
FS-QR120 E floor stand
Copyright Audipack

Advertisement

loading

Summary of Contents for Audipack FS-QR120 E

  • Page 1 Mounting and manual instruction FS-QR120 E floor stand Copyright Audipack...
  • Page 2 It is importand that at first use the lowest lifting head position is set to the correct height. This is importand because the cams on the back of the Audipack bracket on the back of the flat panel should corresond with the key holes of the llifitng head in lowest position.
  • Page 3 Install the top part with the lifting head. Be sure to grip the handle and the side of the colums. Do not lift at the lifting head!! Do not lift the lifting head! Grip handle Make sure both pins slide in equally. At uncontrolled placing it might be more difficult to connect the coloumns.
  • Page 4 Plug in the power supply at the bottom of the lifting head. Lower the lifting head to the lowest position by pressing the lowest button on the back. 230 volt power inlet with loop to the monitor “The right heigth is the height where the cams of the bracket are equally high as the key holes in the lifting head”.
  • Page 5 Flat panel heavier than 85 Kg must use the VESA 400 of 600 mounting pattern of the system. When the screen is equipped with an equal mounting pattern on the back, please contact Audipack for a fitting interface bracket. VESA 400 VESA 600 L&S5...
  • Page 6 Flat panel security. When the flat panel is installed it is possible to lock it onto the lifting head. Release the screws on the top to slide away or position the cover plate. In case of using the standard L&S5 interface a single padlock can be used to secure the set.
  • Page 7 9. Ajusting the lowest height at first use. Be aware that it might be possible your model is equipped with 2 version of adjustment. Please see chapter 9b when the lift is equipped with an electronic height adjustment. The difference is that the electronic version has NO yellow and white adjustment knobs as illustrated below.
  • Page 8 This procedure is only applicable for FS-QR with electronic height adjustment setting. During testing the system is aready set to maximum limits. For the first use the lifting head must be set in height to let the cams from the monitor bracket insert into the key holes of the lifting head (while the flat panel is still in the flightcase).
  • Page 9 -85 Kg with L&S5 mounting interface -120 Kg with VESA 400 and 600 interface (with cams) Power supply 230 VAC 50-60 Hz Max. Motor running time 4 minuten (9 minuten “cool-down” period) For questions or service please contact Audipack 079-5931671 Technical department Notes:...
  • Page 10 Re-programming the controll buttons (pairing). All systems are pre-programmed in the factory. When a new transmitter must be paired to the system check below protocol to perform the “pairing”. Take out the transmitter from the system. Unplug the power for 20 seconds Plug in power for 10 seconds Unplug power for 2 seconds Plug back in the power, the motor will rotate for a few seconds.
  • Page 11 When the system does not respond to the command, a red light will blinck on the remote. Check the battery and replace it. Plug in main power of the system. Function LED Audipack Industriestraat 2 2751 GT Moerkapelle +31(0)79 593 1671...