24579-604

2.6.1 CPCI Plug-In AC Power Supply

Figure 3: Power Supply
Table 1: Data AC Power Supply
e
Input voltage nominal
Mains Frequency
Output (max.)
Output voltages
Ripple
Dynamic response
Recovery time to within 1%
Overvoltage protection
Overcurrent protection
Hold-up time
More information in the user manual order no.: 73972-077

2.6.2 Grounding/Earthing

Caution!
The unit is designed in accordance with protection class 1! It must therefore be
operated with protective earth/GND connection. Use only a three conductor
AC power cable with a protective earth conductor that meets the IEC safety
standards!
www.schroff.biz
100 - 240 VAC
50 / 60 Hz
250 W
3.3
V
-
40
A
5.0
V
-
40
A
12.0
V
-
5.5
A
-12.0
V
-
2
A
< 1 %
< 1 % or 60 mV
< 300 µsec
for all voltages
120 – 130 % U > 5 Vr
105 – 130 % of rated output current
>= 20 ms