Alertmaxx2 Wiring Schematic - Delta Membranes PowerMaxx2 Installation & Operating Manual

Pump station battery backup
Table of Contents

Advertisement

16.0 AlertMaxx2 wiring schematic

12
PowerMaxx2 Battery Backup
(DMS-280-1)
For internal wiring of the battery
backup, please refer to the
PowerMaxx instruction manual.
13 Amp Non-switched
fused spurs
MaxxConnect Cable
Primary
Secondary
From Mains
From Mains
Secondary To Pump/
AMX2 Mains In
- The pump is supplied with a 10m cable.
- When only using the standard 10m
cable attached to the pump, the cable
duct should be no longer than 6m.
- If the cable duct requires to be longer
than 6m, please follow the cable
extension guide to select an appropriate
cable core diameter.
Separate 16 Amp RCBO's
AlertMaxx2 High Level Alarm
(DMS-298)
For internal wiring of the high
level alarm, please refer to the
AlertMaxx2 instruction manual.
Finger Float Switch
Primary To Pump/
AMX2 Mains In
SECONDARY
The electrical installation must comply with the requirements of
BS 7671:2008 'Requirements for
Electrical Installations' incorporating amendment 3:2015
Figure 5. AlertMaxx2 wiring schematic
PRIMARY

Advertisement

Table of Contents
loading

Table of Contents