Commissioning Infographic: Connecting These commissioning instructions requirements a Mobile Terminal to a supplement/are supplemented by: Smart Gateway • Product Information Step-by-step through the Smart Gateway SG 150-0 commissioning process Minimum requirements for • System Manual In-Home bus: stationary internet connection...
Quick overview – Commissioning Observe the safety instructions! Checking, selecting and preparing the network connection Fulfilling commissioning requirements Register product Downloading and installing the bus programming software Programming the Gateway in the In-Home bus and exporting the configuration Login on the Gateway Performing a system update Change user profile / password Setting the date and time...
Safety remarks Observe the safety instructions! Protect your network! If stored images are used as part of Read and observe the safety Only use up-to-date components private / criminal law proceedings or instructions and content of the and terminals in the network in in a police investigation, this requires following documents before using line with the latest state of the art.
(Jung Smart-Control) * From software version 2.0.1, the scope of functions is optionally expandable (see page 25). Internet 3G / 4G Mobile phone with installed Siedle app for Smart Gateway Router/Switch WLAN www.siedle.com Link In-Home SG 150-0 Smart Gateway Status Reset...
Overview Commissioning sequence Mount the Gateway, connect to the In-Home bus / IP network and switch on. See Product Information/ System Manual Configure the Gateway. Optionally: Reserve additional In-Home bus addresses. Programming the In-Home bus (manually or using the bus programming software). Export the In-Home bus configuration from the bus programming software.
Bus addresses in the In-Home bus Connection of bus and IP address As a one-line bus system, the If you are operating the Siedle In-Home bus is restricted to a max- intercom and the Gateway in the imum of 31 bus addresses (bus single-line bus system, each com- users).
Overview Example – Single line system Example – Multiple line system System limits Use of one bus line. Use of at least 2 but no more than Gateway 15 bus lines. Installation example Characteristics: Quantity The Siedle call station comprises Installation example Maximum number of 2 door stations (main and side...
Preparation Menu structure User interface Menu level 1 Menu level 2 Status Overview IP users Device information User User profile Change the password Basic settings Date / time Network Video memory / Door call Video Call number prefixes In-Home bus Bus adresses Bus users Network user...
Preparation Information on programming Remarks on the Finder function In order to use the door intercom In the bus programming software system, at least one door call must (BPS), the Finder function can be be programmed in the In-Home bus. used in order to determine the IP Programming is described in detail address of the Gateway.
Network/Network settings with the aid of a dedicated network scanner. • For regular operation, a perma- www.siedle.com Link In-Home SG 150-0 Smart Gateway Status nent static IP address is required. Reset IP 20 0000000000000 Prog. This ensures that the Gateway can always be reached under the same SG 150-...
12 The network settings are now highlighted in white and can be changed. 13 Execute the changes at the net- www.siedle.com Link In-Home SG 150-0 Smart Gateway Status Reset IP 20 work settings. 0000000000000 Prog. 14 Click on the “Apply” button.
• Siedle finder (component of the bus programming software installation) • Standard web browser (latest version) Required documentation • Product information Smart Gateway Professional SG 150-0 • Commissioning instruction • System Manual In-Home bus: Video (Latest edition) Required hardware • Commissioning laptop/PC •...
Commissioning requirements Fulfilling commissioning Step-by-step through the Register product requirements commissioning process Siedle software is continuously In order to allow the Gateway to be The following commissioning steps updated and further developed. To commissioned, the following work are described over the following ensure that you make use of all the must have been completed: pages:...
• Program the users for larger-scale projects. • Quit the programming mode www.siedle.com Link In-Home SG 150-0 Smart Gateway Status Reset IP 20 0000000000000 Prog. 1 Switch on the programming mode. 2 At the door station, hold down 3 The In-Home LED at the Gateway At the BNG/BVNG 650-…, press the...
Commissioning Programming using the PC Performing a system update 12 Click the Update system button. and bus programming software Every time before updating the During this update process, the (BPS 650-…) system (upgrade/downgrade), carry Gateway and then the connected Log into the Gateway using one of out a complete system backup.
Change user profile / password Check/change the Door call option settings: Procedure: network settings 7 Activate the direct door call if you 1 Click on User > User profile. wish users to be able to call door call 2 Change/Complete the input fields. Procedure: stations directly.
11 Export the XML configuration 7 Click on Save. Gateway. file for the Smart Gateway (BPS: A storey call can be assigned to one SG 150/650 > Create configuration Deleting IP users or more IP users (IP group)(except file …) and save this (e.g.
Play Store. three additional function licenses can 5 Click on Apply to save your set- 2 Create a new IP user (Siedle App) be purchased for the Smart Gateway in the Smart Gateway. SG 150-0:Bus license for BLSHT tings/changes. 3 A QR code is generated on the...
Commissioning Set up SIP client Link Siedle Axiom 1 Click on Network user > Telephony Procedure: 1 Create the Siedle Axiom in the connection. 2 Click on Create connection. Gateway as an IP user. 3 Select the required mode (SIP 2 Under Network users >...
2 Update the Gateway 3 Install or update Siedle App on the mobile device. 4 Change the Gateway configuration. 5 Commission the Siedle app. 6 Complete function check. Infographic: Connecting a Mobile Terminal to a Smart Gateway Siedle App Indoor station QR-Code WLAN...
1 Create a new IP user (Siedle App) work connection via 3G/4G/5G can not impair or prevent the internal in the Smart Gateway. be configured according to the fol- and external accessibility of the 2 A QR code is generated on the lowing description.
• Stable WLAN or mobile • Download: constant at phone connection least 512 kBit/s (3G/4G/5G) • Upload: see page 22 • SIP-VoIP enabled • SIP-VoIP enabled • Public IP: static or dynamic WLAN www.siedle.com Link In-Home SG 650-0 Smart Gateway Status Reset IP 20 0000000000000 Prog.
Yes if you wish to finder. Alternatively, the IP address the system documentation and the reset the Gateway. of the Smart Gateway can be deter- changed access data to the cus- mined through the DHCP server or tomer/system administrator.
LED1 flashes on the BNG/ three additional function licenses can bus, the Gateway requires additional BVNG. be purchased for the Smart Gateway In-Home bus addresses. 8 If the required number of In-Home SG 150-0:Bus license for BLSHT For each IP user / group which you...
Optional commissioning steps Logging Remark: Configuration data: The Gateway benefits from extensive The logs are not included in the All settings are backed up and system logging. The logs are located system backup. If you wish to reset restored in one file (file format: in the submenu Logs (System >...
Page 27
Index Accessibility of the Gateway Integrable networking Siedle Axiom 19, 20 components Single line system 7, 8 IP address and password reset As-delivered status Step-by-step through the IP users 5, 8, 18, 25 commissioning process Automatic logout Jung TKM Client Storey call – Backing up/ Defining IP users/IP group Restoring the system Legal notice System limits...