(3-6) SYSTEM EXCLUSIVE MESSAGE
(3-6-1) YAMAHA MIDI FORMAT
(3-6-1-1) SECTION CONTROL
binary
11110000
0!00001"1
01111110
00000000
Osssssss
0ddddddd
111 IOI 11
hexadecimal
F0
43
7E
00
ss
DD
F7
Exclusive status
- YAMAHA ID
Style
Switch No.
OOH
:INTROA
0IH-07H : INTRO B
08H
:MAINA
09H~0FH : MAIN B
JOH
:FILLINAA
l lH~ 17H : FILLIN BB
18H
:FILLINAB
19H~IFH :FILLINBA
20H
: ENDING A
21Hc-27H : ENDING B
Switch On/Off: OOH( Oft), 7FH(On)
End of Exclusive
When an ON code is received, the appointed section will be changed.
(3-6-1-2) TEMPO CONTROL
binary
hexadecimal
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
OJ I I I 110
7E
Style
00000000
01
0ttttttt
TI
Tempo4
0ttttttt
TI
Tempo3
0ttttttt
TI
Tempo2
0ttttttt
TI
Tempo!
11110111
F7
End of Exclusive
The internal clock will be set to the received Tempo value.
Tempo Meta Event is a large data block (24-bit), it is divided into 4 groups with 7-bits
going into each of the Tempos 1-4 (4 receives the remaining 3 bits).
(3-6-2) UNIVERSAL SYSTEM EXCLUSIVE
(3-6-2-1) UNIVERSAL REALTIME MESSAGE
(3-6-2-1-1) MIDI MASTER VOLUME (Recive only)
binary
hexadecimal
11110000
FO
0IIIIIIO
7F
01111111
7F
00001001
04
00000001
01
0sssssss
SS
0ttttttt
TI
11110111
F7
or
11110000
01 I 11110
Oxxxnnnn
00001001
00000001
Osssssss
01111111
11110111
FO
7F
XN
04
01
ss
TI
F7
Exclusive status
Universal Realtime
ID of target Device
Sub-ID #!=Device Control Message
Sub-ID #2=Master Volume
Volume LSB
VolumeMSB
End of Exclusive
Exclusive status
Universal Realtime
When N is received N=O-F, whichever is received.
When N is transmitted N always=0.
X = don't care
Sub-ID #!=Device Control Message
Sub-ID #2=Master Volume
VolumeLSB
VolumeMSB
· End of Exclusive
The volume for all channels will be changed simultaneously.
The TT value is used as the MIDI Master Volume value .. (the ss value is ignored.)
(3-6-2-2) UNIVERSAL NON REALTIME MESSAGE
(3-6-2-2-1) GENERAL MIDI SYSTEM ON
binary
Ill 10000
01111110
01111111
00001001
00000001
11110111
or
hexadecimal
F0
7E
7F
09
01
F7
Exclusive status
Universal Non-Realtlme
ID of target Device
Sub-ID #!=General
MIDI
Message
Sub-ID #2=General MIDI On
End of Exclusive
CVP-96/CVP-98
11110000
F0
Exclusive status
01111110
7E
Universal Non-Realtime
Oxxxnnnn
XN
When N is received N=O-F, whichever is received.
When N is transmitted N always=0.
X = don't care
00001001
09
Sub-ID #!=General MIDI Message
00000001
01
Sub-ID #2=General MIDI On
11110111
F7
End of Exclusive
Depending upon the received ON message, the System Mode will be changed to XG.
Except MIDI Master Tuning, ail control data be reset to default values.
ThiS message requires approximately 50ms to execute, so sufficient time should be
allowed before the next message is sent.
(3-6-3) XG STANDARD
(3·6-3-1) XG PARAMETER CHANGE
(3-6-3-1-1) XG SYSTEM ON
binary
hexade.cimal
Ill 10000
F0
Exclusive status
01000011
43
YAMAHA ID
0OO!nnnn
IN
Device Number
01001 JOO
4C
Model ID
00000000
00
Address High
00000000
00
Address Mid
Oil 11110
7E
Address Low
00000000
00
Data
11110111
F7
End of Exclusive
Depending upon the received ON message, the SYSTEM MODE will be "changed to
XG.Controllers will be reset, all values of Multi Part and Effect, and All System
values denoted
by "XG" data within All System
will
be reset to default values in the
table.
This message requires approxfmately 50ms to execute, so sufficient time should be
allowed before the next message is sent.
(3-6-3-1-2) XG PARMETER CHANGE
binary
hexadecimal
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
000!nnnn
IN
Device Number
01001100
4C
Model ID
Oaaaaaaa
AA
Address High
Oaaaaaaa
AA
Address Mid
Oaaaaaaa
AA
Address Low
0ddddddd
DD
Data
I
11110111
F7
End of Exclusive
For parameters with data size of 2 or 4, transmit the appropriate number of data bytes.
For more information on Address and Parameters, refer to< Table 1-2 > (page 92) and
< Table 1-4 > - < Table 1-8 > (pages 93-97).
The 4 data types listed below are transmitted and received.
(These are transmitted only after a Parameter change request is received.)
XG System Data
Multi Effect Data
Multi EQ Data
Multi Part Data
Drums Setup Data
(3-6-3-2) XG BULK DUMP
binary
hexadecimal
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0OO0nnnn
ON
Device Number
01001100
4C
Model ID
0bbbbbbb
BB
ByteCount
Obbbbbbb
BB
ByteCount
Oaaaaaaa
AA
Address High
0aaaaaaa
AA
Address Mid
0aaaaaaa
AA
Address Low
0ddddddd
DD
Data
I
I
Occccccc
cc
Checksum
11110111
F7
End of Exclusive
For more information on Address and Byte Count, refer to < Table 1-2 >~<Table 1-8 >
(pages 92,97 ).
The Check Sum value is sei such that the sum of Byte Count, Address, Data, and
Check Sum has value zero in its seven least significant bits.
If the top of the block is appointed to the Address the XG Bulk Dump, Bulk Request
will be received.
The Block is a unit that consists of the data, arranged in the Hst, as the Total Size.

Advertisement